Atop Serial Device Server
SE5002D
User Manual V. 1.1
3.2.6
Configure SE5002D as a TCP Client
Fig. 3. 8
Type
2
in the
“Input choice (1~5) and enter:”
Input destination IP in the
“Please input Destination IP:”
Input destination port in the
“Please input Destination port:”
Select TCP connection behavior:
1
for connect always,
2
for connect on serial data.
If
“2”
is selected, the console will prompt for additional configurations.
Input idle time to disconnect in the
“Please input idle time to disconnect (0se,
1~255):”
(Input
0
to disable; input
2
to disconnect TCP connection after 2 seconds
of serial inactivity).
Input error retrying time in
“Please input waiting time for error retrying (0 minute,
1~255):”
(input 0 to disable; input 2 to try to connect to a TCP Server every 2
minutes).
Input idle time in
“Please input idle time to send TCP alive packet (x*10sec):”
(input
2 to send TCP keep alive packet every 20 seconds).