Figure 2.13 Webpage to Configure System DIP Switch
2.1.7
Alert
This webpage allows the users to configure how each type of the power status alarm events will be sent or notify the users.
Power Status Alarms keep track of power status of the switch based on the available input connectors.
EH9711 supports two to three power sources. In the example,
Power1
and
Power2
are illustrated as shown in Figure 2.14
Users can enable a notification of each power source separately. Also, they can get notifications through many methods
including
Relay
,
Alarm LED
, and
by selecting
Enabled
in any of these fields. Click
Save
button to let the setting take
effect, or click
Reset
button to change back to the previously saved values.
Figure 2.14 Webpage to Configure System Alert
Table 2.10 summarizes the Power Status Alarm event selection.
Table 2.10 Descriptions of Power Status Alarm Event Selection
Label
Description
Factory Default
Power
Indicate specific power supply such as Power 1 and Power
2
-
Relay
Options: Disabled, Power On, or Power Off
Disabled
Alarm LED
Options: Disabled, Power On, or Power Off
Disabled
Options: Disabled, Power On, or Power Off
Disabled
2.1.8
SMTP Setting
S
imple
M
ail
T
ransfer
P
rotocol (
SMTP
) is an internet standard for e-mail transmission across IP networks. In case any warning
events occur, the system can send an alarm message (e.g., Link Status and System Log) to users by e-mail. As shown in Figure
2.15, users can enable/disable server’s authentication, input user name and password if enabled, and edit email address of the
sender and four recipients. The total of four recipients are allowed to receive an e-mail.