* Record model: non-cycling and cycling available.
Non-cycling: the cycling recording will stop automatically when there is no recording space left or there are
already 100 records: when the recording space is used up, the recording will continue from the first file and record
the historical data in the circle of replacing the previous files with new files; and when there are already 100 files,
the first file will be deleted at first, the document number of the rest files will be changed to those of the previous
ones, and the new file will be created to continue the recording.
* Recording interval: 1 s, 2 s, 4 s, 6 s, 15 s, 30 s, 1 minute, 2 minute and 4 minute are optional.
* Record type: real-time value, average value, maximum, and minimum are optional.
Real-time value: it is the real-time value corresponding to the recording time.
Average value: it is the average value of the values of two successive recording points calculated with
weighted average calculation method.
Maximum: it is the maximum value of the real-time values of two successive recording points.
Minimum: it is the minimum value of the real-time values of two successive recording points.
* Recording after power-on: new file and before power-down are optional.
New file: the recording is carried out by creating new files after the power is on.
Before power-down: the recording is continued following the files created before power-down; the data
during the outage period is showed as -.—when this function is selected.
* Triggering conditions: manual, power-on, alarm, relay and timing are optional (Notes: the following
changeable triggering methods will be displayed when the corresponding triggering condition is selected)
Manual trigger: the data storage recording can be stopped or started manually after the storage interface of
the instrument is opened.
Power-on: new files will be created and data recording will be started after the power is on and the
instrument is started.
Alarm trigger: the data storage recording will be started when there is certain alarm corresponding to certain
channel, and the recording will be stopped when the alarm ends.
Relay trigger: the data storage recording will be started when certain relay alarms, and the recording will be
stopped when the alarm ends.
Timed trigger: the timed cycle period is fixed at 24 h, and the starting time and end time can be set, so the
instrument will record the stored data within specified period.
Operation:
in
this
menu
The
cursor
can
be
moved
by
pressing
the
"Left"
or
the
"Right"
key;
The
values
can
be
adjusted
by
pressing
"Up",
"Down",
"Increase",
or
"Decrease"
key;
Automation www.ato.com [email protected] Global Shipping +1 800-585-1519 (Toll-free)
Paperless Recorder
1
8