5.11. FACTORY
SETTINGS
ELEVATION SETTING
NOTES:
The hydraulic oil temperature must be above 25°C
The elevation block limiter is set at 160b
The total weight in the basket is 240 kg
The motor rate is 1370 rpm
Values in seconds
Values in mA
Low station attitude (without
weight)
Up
15 to 23
Refer to the ICAN "default values" page
Down
High station attitude test
(with weight)
Up
Must lift the max weight
Refer to the ICAN "default values" page
Down
1 person in the basket, movement must
be fluid
Rotator G (180°)
15 to 20
Refer to the ICAN "default values" page
Rotator D (180°)
Tower G (180°)
42 to 50
Refer to the ICAN "default values" page
Tower D (180°)
Jib Up
13 to 18
Refer to the ICAN "default values" page
Jib Down
Arm 1 Up
17 to 25
Refer to the ICAN "default values" page
Arm 1 Down
14 to 22
Arm 2 Up
14 to 22
Refer to the ICAN "default values" page
Arm 2 Down
12 to 20
Telescope Out
14 to 22
Refer to the ICAN "default values" page
Telescope In
12 to 20
SIDEWAYS MOVEMENT SETTING
NOTES:
The hydraulic oil temperature must be above 25°C
The elevation block limiter is set at 160b
The total weight in the basket is 240 kg
The motor rate is 1370 rpm
Values in seconds
Values in mA
"Low speed" Forward/Reverse over a distance of
25 metres
95 to 105
Refer to the ICAN "default values" page
"High speed" Forward/Reverse over a distance of
50 metres
25 to 35
Refer to the ICAN "default values" page
"Slope speed" Forward/Reverse over a distance
of 50 metres
65 to 75
Refer to the ICAN "default values" page