5.8
Outside wall and roof outlet concentric terminal
horizontal
Appliance category: C13
CAUTION
Pipes for connecting the air supply and the flue discharge
between the appliance and the terminal must have a
diameter of 80 mm.
A.
Atmos concentric terminal horizontal.
For outside wall or roof outlet horizontal.
B.
Atmos concentric pipe.
For extension of a balcony/gallery outlet.
Maximum pipe length
See §5.6.
Flue discharge and air supply pipes
For mounting, see § 5.6.5.
Mounting 80/125mm horizontal terminal
B
1.
Make an opening of diameter 130 mm at the place of the outlet.
2.
Shorten the terminal to the length required.
3.
Mount the outlet grid and attach this to the inside pipe.
4.
Slide the terminal into the opening and fit rosettes to cover the
opening.
5.
Ensure the pipes slope back to the appliance.