4.6
Mount the appliance
1.
Check whether the clamping rings are straight in the couplings.
2.
Place the appliance: slide it top-down over the mounting strip. Make
sure that the pipes simultaneously slide into the clamp fittings.
3.
The flexible tube from the condensate siphon should be inserted
into an open waste pipe of not less than 32 mm diameter. If
connected to a soil pipe or waste system, the waste pipe must
include a trap (similar to arrangement for washing machine).
The 15 mm safety discharge copper pipe from the pressure relief
safety valve may also be taken into this pipe (as shown in the
diagram, §5.1) or, alternatively, taken to a safe discharge position
on the outside wall of the building.
4.
Tighten the clamping fittings to the mounting bracket.
5.
Mount the air supply and the flue discharge.
6.
Close the air supply opening that is not used with the plug supplied.
4.7
Fit the pipework cover
1.
Insert the four hooks of the pipework cover in the slots of the
appliance.
2.
Slide the cover backwards, sliding the hooks into the slots and
locking the cover.
18