The safety thermostat
- located on the fuel supply pipe of the burner, will shut down the burner
if its temperature is higher than 95 °C. Thus, it protects the burner from return ignition of pellets
in the conveyor and at the same time from operation with clogged flue gas exhaust from the boiler
(e.g. in case of a failure to remove dust from the boiler, flue gas duct and chimney). The safety
thermostat will also put the burner out of operation in case the hose between the burner and con-
veyor gets perforated to prevent flue gas from escaping to the boiler room.
INFO
- After any shutdown of the burner when an error message (ALARM) appears on
the display it is necessary to immediately find the cause and remove it. After removing the
cause of the error you can start the burner by merely
turning off and on the burner switch
,
which is located on the boiler panel.
Basic dimensions of the opening for installation of the burner in a boiler
In the case of the D30P, D31P, P31 and D45P boil-
ers the burner is fastened to the frame of the boiler
with sealing cord - 18x32 mm.