G
B
www.atmos.cz
16-GB
Operation and Maintenance Manual - GB
9. Basic connection diagram of a D30P, D31P, P31 a D45P
boiler with an accumulation tank for burner control on the
basis of TS and TV sensors
INFO
– The TV and TS sensors on the accumulation tank are connected directly to the
burner. The AD02 module is inserted under the instrument hood of the boiler and is con-
nected to the terminal board of the boiler (AD02 module - LA clamp), where it controls the
extraction fan of the boiler.
Required accessorie
s (not part of the burner): A02 module and two KTF 20 sensors – recommended
for purchase as the
AS25 set.
System configuration of parameters:
S6 = 4, S14 = 0, S15 = 2
(Reserve R – parameter S6 controls the boiler fan)
WARNING
– the AD02 module may be replaced by an AD03 module, whereas only the
required output is used (module AD03 – LA clamp)
The pump in the boiler circuit is controlled by the directly installed thermoregulator from the boiler
panel.
A45