background image

Outdoor Fire Pit Pro Spur Burners with

Match Throw (MT) Ignition System

Installation and Operating Instructions

IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS 

DO NOT  ATTEMPT TO INSTALL OR OPERATE THIS APPLIANCE

DO NOT DISCARD.  THIS MANUAL 

HAS IMPORTANT OPERATING AND 

MAINTENANCE INSTRUCTIONS.  

LEAVE WITH THE HOMEOWNER

.

Warning:

  For Outdoor Use Only

INSTALLATION PRECAUTION

 

This system requires a minimum 18-square inches (per side) of cross ventilation. 

Failure to provide proper ventilation will void the warranty.

Natural Gas Models

Propane Gas Models

Description

FPB-19RPSBR14MT-N FPB-19RPSBR14MT-P 19” Round Pan with 14” Pro Brass Burner
FPB-25RPSBR21MT-N FPB-25RPSBR21MT-P 25” Round Pan with 21” Pro Brass Burner
FPB-29RPSBR21MT-N FPB-29RPSBR21MT-P 29” Round Pan with 21” Pro Brass Burner
FPB-33RPSBR21MT-N FPB-33RPSBR21MT-P 33” Round Pan with 21” Pro Brass Burner
FPB-20SPSBR14MT-N FPB-20SPSBR14MT-P 20” Square Pan with 14” Pro Brass Burner
FPB-26SPSBR21MT-N FPB-26SPSBR21MT-P 26” Square Pan with 21” Pro Brass Burner
FPB-32SPSBR21MT-N FPB-32SPSBR21MT-P 32” Square Pan with 21” Pro Brass Burner

Round Pan

MODEL:
SERIAL #:

PN#90088

Square Pan

“PRO SERIES”

Summary of Contents for FPB-19RPSBR14MT-N

Page 1: ...provide proper ventilation will void the warranty Natural Gas Models Propane Gas Models Description FPB 19RPSBR14MT N FPB 19RPSBR14MT P 19 Round Pan with 14 Pro Brass Burner FPB 25RPSBR21MT N FPB 25RP...

Page 2: ...ff gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department DANGER WARNING Do not store or use gasoli...

Page 3: ...lace WE HIGHLY RECOMMEND COVERING ALL FIRE FEATURES WHEN NOT IN USE The use of a cover can lessen the impact of thermal spalling however heavy rains high humidity and the presence of moisture may stil...

Page 4: ...r Size D Ground Level E Side Wall F Combustible Ceiling G Combustible Floor FPB 19RPSBR14MT N FPB 19RPSBR14MT P 2 19 Rd 14 8 36 120 18 FPB 25RPSBR21MT N FPB 25RPSBR21MT P 2 25 Rd 21 8 36 120 18 FPB 29...

Page 5: ...s required for the amount of BTU s for a new gas line installations If you are using an existing gas line you must take into consideration the existing gas line capacities to ensure you will have prop...

Page 6: ...ontents The box includes a flex gas line key valve flange key and flared fitting with nipple Inspect for any damage or missing parts See Fig 4 Install the flared fitting and nipple into the bottom of...

Page 7: ...ten 2 Extend the gas supply system using minimum of black iron pipe or an approved flexible gas line from existing house supply This can be accomplished by teeing off or tapping into a gas line connec...

Page 8: ...outdoor use only Not approved for any indoor use 9 This fire pit is designed to have lava rock completely covering the spur burner so that the burner is not visible Do not cover more than 1 above the...

Page 9: ...s Supply Key Valve Side View Det a i l Fig 7 Typical installation NOTE Key valve and flexible gas lines are supplied Gas shut off is not supplied Note A 1 x 2 black iron or galvanized coupler nipple n...

Page 10: ...connection before each use of the appliance 6 Temporary storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply Natural or L P gas line WARNING 1 This ap...

Page 11: ...REV A Page 11 FPB Pro Spur Burners Fire Pits with MT System MT REPLACEMENT PARTS 1 2 6 3 8 4 9 10 Drawings not to scale O N O F F 7 5...

Page 12: ...use a ventilated cover overtop of your fire pit to protect it from humid rainy weather conditions when not in use Heavy rains downpours could affect the fire pit operation if not covered if this occur...

Page 13: ...Web Site www firegearoutdoors com 800 966 8126 See Firegear Outdoors catalog for other accessories E STOP Gas shut off valve with mechanical timer and emergency shut off Models ESTOP1 0H 1 hour timer...

Page 14: ...D S Fitting Fire Pit Disc Inlet Gas Supply Expanded View of Match Throw MT Fire Pits T200 9898 46 Flex Connector Note Use joint compound or Teflon tape resistant to all gasses on all male NPT threads...

Page 15: ...VE 5 YEAR WARRANTY REFRACTORY GAS LOG SETS FIVE 5 YEAR WARRANTY READY TO FINISH ANF FIRE PIT ENCLOSURES FIVE 5 YEAR WARRANTY SKYTECH MANUACFTURED OPTIONAL CONTROLS OUTDOOR FIREPLACE KALEA BAY LIFETIME...

Page 16: ...FIREPLACE KALEA BAY LIFETIME WARRANTY CONSTRUCTION AND MANUFACTURER DEFECTS LIFETIME WARRANTY STAINLESS STEEL COMPONENTS TWO 2 YEAR WARRANTY GAS VALVE PILOT ASSEMBLY POWER SUPPLY CONTROLS TWO 2 YEAR...

Page 17: ...o repair the defect on warranty parts to and from the factory will be the responsibility of the owner We will not be responsible for labor charges and or damage incurred in installation repair and rep...

Page 18: ..._______ 2 Serial Number ___________________________ 3 How long is the gas line run Nat Gas ____ LP Gas ____ 4 What size is gas line _____ 5 Inlet Gas Pressure _____WC Manifold Gas Pressure _____ WC 6...

Reviews: