AT-GAIN-60
27
Control page
The Web GUI
Power
Click the
ON
button to power-on the AT-GAIN-60. Click the
OFF
button to power-off the unit.
Auto Power Down
Enables or disables auto power down mode. Refer to
Auto Power Down mode (page 19)
for more information.
Auto Power Down Time (min)
Specify the time interval before the AT-GAIN-60 goes into auto power down mode. Refer to
Auto Power Down mode
(page 19)
for more information. The default setting is 15 minutes.
Factory Default
Click this button to reset the AT-GAIN-60 to factory-default settings.
Blink
Click the
Blink
button to start blinking the
PWR
LED indicator. This feature is useful to identify the unit when multiple
units are being used.
RS-232
Sets the RS-232 settings used by the control device. The default settings are 115200, 8, None, 1.
Setting
Description
Baud rate
Sets the baud rate. The following options are available:
110, 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200.
Data bit
Sets the number of data bits used to represent each character of data. The following
options are available: 5, 6, 7, or 8.
Parity
Sets the parity bit, which can be included with each character to detect errors during
the transmission of data. The following options are available: None, Odd, or Even.
Stop bit
Sets the stop bit. Stop bits are sent at the end of each character, allowing the client
to detect the end of a character stream. The following options are available: 1 or 2.