AT-GAIN-60
19
Basic Operation
Power Modes
The following section discusses the power mode features which have been integrated into the AT-GAIN-60.
Power modes are located under the
Control
tab within the web GUI.
Click the
OFF
option to power-off the AT-GAIN-60. When powered-off, audio output is disabled but the
LAN
port will
remain active. To power-on the AT-GAIN-60, after it has been powered-off, any one of the following methods may be
used:
• Set
Power
to the
ON
setting, in the web GUI.
• Execute the
PWON
command using RS-232 or Telnet.
•
Press any of the buttons on the front panel to wake the unit.
1.
Open the desired web browser and enter the IP address of the AT-GAIN-60.
2.
Log in, using the required credentials. The factory-default username and password are listed below:
Username:
admin
Password:
Atlona
3. Click the
Control
tab, located on the side menu bar. The
Control Settings
section will be displayed.
Powering On or Off
Enabling this mode will automatically power-down the AT-GAIN-60 if no audio input signal is present on either the
AUDIO IN 1
port or the
AUDIO IN 2
port, after the specified time interval. When the AT-GAIN-60 enters Auto Power
Down mode, the Power option will be set to
OFF
and the front-panel LED indicators will turn off. In Auto Power
Down mode, power consumption is limited to 1.2 W. By default this feature is enabled.
Note that when this mode is enabled, the AT-GAIN-60 only monitors the existence of an audio input signal, not the
physical audio connection. Refer to the next page for instructions.
Auto
Power Down mode