10.30
10.30
Electrical
Electrical system
system
A
AT
TL
LE
ET
T
S
SE
ER
RV
VIIC
CE
E
M
MA
AN
NU
UA
AL
L
A
Attlleett''s
s
ttrru
ucck
k
cco
om
mp
pu
utteer
r
A
AT
TC
C
10.
10.1
11.5
1.5 Cali
Calibrat
bration a
ion and co
nd contro
ntrol of the h
l of the hydra
ydraul
ulic lev
ic levers
ers
Hydraulic levers are calibrated by measuring the
Hydraulic levers are calibrated by measuring the maximum stroke and neutral
maximum stroke and neutral
position for this function. See chapter 8.
position for this function. See chapter 8.
10
10.1
.11.6
1.6 Run
Runnin
ning t
g time
ime fu
func
nctio
tions
ns
The running times of the following functions can be read:
The running times of the following functions can be read:
•• T
To
ottaal u
l ussaag
gee..
•• Pu
Pump
mp mo
moto
tor o
r on 5 l
n 5 lev
evel
els.
s.
•• F
Fo
orrw
waarrd
dss..
•• B
Baacck
kw
waarrd
dss..
The running time of each function presented in hours. The maximum number of
The running time of each function presented in hours. The maximum number of
hours is 99999. When printing the
hours is 99999. When printing the running hours are also calculated and shown as
running hours are also calculated and shown as
a percentage of the total usage. The running hours can either be reset for all units or
a percentage of the total usage. The running hours can either be reset for all units or
individually.
individually.
10
10.1
.11.7
1.7 Pri
nting
ing of
of st
stati
atist
stics
ics
A function is available under CUSTOMER Service to print all statistical functions
A function is available under CUSTOMER Service to print all statistical functions
either individually or all at once. Any serial printer
either individually or all at once. Any serial printer or a PC can be used for
or a PC can be used for this
this
purpose.
purpose.
10
10.1
.11.
1.8
8 Co
Coll
llis
isio
ion se
n sens
nsor
or
This function requires a special sensor mounted on
This function requires a special sensor mounted on the chassis.
the chassis.
The program has 5 adjustable limits and when one of these is exceeded one or more
The program has 5 adjustable limits and when one of these is exceeded one or more
of the f
of the following functions are activated:
ollowing functions are activated:
1.
1.
A wa
A warn
rnin
ing m
g mes
essa
sage i
ge is s
s sho
hown
wn on
on th
the d
e dis
ispl
play
ay..
2.
2.
The t
The truc
ruck's n
k's norm
ormal ho
al horn is a
rn is acti
ctiva
vated a
ted and pr
nd produ
oduces a
ces an int
n interm
ermitt
ittent s
ent sign
ignal.
al.
3.
3.
Th
The wa
e warn
rnin
ing la
g lamp
mp on t
on the
he tru
truck
ck li
ligh
ghts/
ts/fla
flash
shes
es..
4
4..
T
Th
he
e ttrru
ucck
k llo
og
gs
s o
offff..
5.
5.
A sp
A spec
ecia
ial pa
l pass
sswo
word i
rd is re
s requ
quire
ired to s
d to sto
top th
p the ab
e abov
ove.
e.
When one of the 5 levels is exceeded a warning text is shown on the display at the
When one of the 5 levels is exceeded a warning text is shown on the display at the
same time as the impact force of the collision is stored with t
same time as the impact force of the collision is stored with the time, date and driver
he time, date and driver
ID in the customer log.
ID in the customer log.
10
10.1
.11.
1.9
9 A
ATC c
TC co
onn
nnec
ecto
torr
ATC, contactor and pin
ATC, contactor and pin numbering. Fuses, see section 10.9 Fuses.
numbering. Fuses, see section 10.9 Fuses.
https://www.besttruckmanuals.com/