E102, E107 Subinfo: Internal Motor / Controller Fault
E102, E107 Subinfo: Internal Motor / Controller Fault
..
E103, E107 Subinfo: Controller rev to default.
E103, E107 Subinfo: Controller rev to default.
E102, E107 Subinfo: CAN watchdog time out.
E102, E107 Subinfo: CAN watchdog time out.
R
Reep
pllaacce
e E
EP
PS
S u
un
niitt
T
Th
hiis
s eerrrro
or
r aarriissees
s w
wh
heen
n tth
he
e llo
oaad
d
impedance which the EPS unit's
impedance which the EPS unit's
power stage measures, is too high
power stage measures, is too high
for the EPS 2001 to be able to
for the EPS 2001 to be able to
correctly regulate the motor
correctly regulate the motor
current.
current.
Disconnect the current to the EPS
Disconnect the current to the EPS
2001 with help of the battery
2001 with help of the battery
cable. Wait 15 seconds and
cable. Wait 15 seconds and
reconnect the battery to the EPS.
reconnect the battery to the EPS.
This error occurs when the EPS
This error occurs when the EPS
2001 has registered incorrect user
2001 has registered incorrect user
parameters and returned to preset
parameters and returned to preset
parameters.
parameters.
Has the problem occurred again,
Has the problem occurred again,
after the EPS 2001 has been
after the EPS 2001 has been
restarted?
restarted?
šš
No
No
Finished.
Finished.
Y
Yes
es
Replace EPS unit.
Replace EPS unit.
Is the CAN bus cabling between
Is the CAN bus cabling between
the A
the ATC and EPS 2001 i
TC and EPS 2001 intact? Is
ntact? Is
12V DC present between the
12V DC present between the
E4.12 and E4.3 connections
E4.12 and E4.3 connections
šš
No
No
If the cabling is faulty, repair or
If the cabling is faulty, repair or
replace If 12V DC is not present,
replace If 12V DC is not present,
check that the
check that the A
ATC gives +12V
TC gives +12V
DC on the XC9.12 connection a
DC on the XC9.12 connection and
nd
0V on XC9.7. (If there is an error
0V on XC9.7. (If there is an error
on the +12V DC, the lamps in the
on the +12V DC, the lamps in the
truck will not work.)
truck will not work.)
Y
Yes
es
R
Reep
pllaacce
e E
EP
PS
S u
un
niitt..
C
Ch
heecck
k ffo
or
r eerrrro
orrs
s iin
n tth
he
e +
+1
12
2V
V D
DC
C
supply. It is appropriate to
supply. It is appropriate to
disconnect all computer
disconnect all computer
connectors except XC9 and check
connectors except XC9 and check
that 12V DC is present between
that 12V DC is present between
XC9.12 and XC9.7.
XC9.12 and XC9.7.
This error occurs if the EPS 2001
This error occurs if the EPS 2001
does not receive a sync or PDO
does not receive a sync or PDO
message within a specified time.
message within a specified time.
Replace computer.
Replace computer.