- 123 -
Specific fuel consumption
at 100% FAD
at 25 bar (363 psi)
pressure setting
without aftercooler
g/m
3
-
36.9
36.5
lb/1000 cu.ft
-
2.30
2.27
with aftercooler
g/m
3
-
38.1
38.1
lb/1000 cu.ft
-
2.38
2.38
Specific fuel consumption
at 100% FAD
at 30 bar (435 psi)
pressure setting
without aftercooler
g/m
3
-
37.9
-
lb/1000 cu.ft
-
2.37
-
with aftercooler
g/m
3
-
39.2
-
lb/1000 cu.ft
-
2.45
-
Specific fuel consumption
at 100% FAD
at 35 bar (508 psi)
pressure setting
without aftercooler
g/m
3
42
-
-
lb/1000 cu.ft
2.62
-
-
with aftercooler
g/m
3
43.5
-
-
lb/1000 cu.ft
2.71
-
-
Typical oil content of compressed air
mg/m
3
free air
3
3
3
oz/1000 cu.ft
0.003
0.003
0.003
Compressed air temperature
at outlet valve
without aftercooler
°C
102
102
102
°F
216
216
216
Air volume at inlet grating (approx.)
3)
m
3
/s
15.1
14.6
16.3
cu.ft/s
530
513
573
Noise level
- Sound pressure level (LP) at 7 m distance
dB(A)
80
78
80
- Sound power level (LW) is measured according
to ISO 3744
dB(A)
108
106
108
Designation
XRYS 577 - XRYS 1260
XRXS 607 - XRXS 1275
XRVS 647 - XRVS 1350
1)
Free air delivery is measured according to ISO 1217 ed.4 2009 annex D
Tolerance:
•
+/- 5% 25 l/s (53 cfm) < FAD < 250 l/s (530 cfm)
•
+/- 4% 250 l/s (530 cfm) < FAD
2)
To account for fuel used during regeneration the fuel consumption values have
to be increased with 1.5%. This is an average percentage and is dependent on
the working conditions of the compressor.
3)
Air required for engine and compressor element cooling, for combustion and
for compression.