Connecting the I/O tester
2.
Connect the 5-position connector on the I/O tester to an unoccupied 5-position con-
nector in the I/O module.
3.
Connect the multimeter between GND and the +A or +B output that is of interest.
4.
Activate the function. Normally, the multimeter will read ~ 24V.
Fault indication
n
If the valve is not activated, there is an open circuit in the cable running to the valve or
in the coil in the valve.
Measuring current
1.
Connect the 5-position connector on the I/O tester between the output of interest on
the I/O module and the valve as illustrated.
Connecting the I/O tester
Summary of Contents for SMARTROC D65 TIER 4 FINAL
Page 2: ......
Page 4: ......
Page 10: ...SmartROC D65 Tier 4 Final Table of Contents x...
Page 32: ...SmartROC D65 Tier 4 Final 2 General 32...
Page 38: ...SmartROC D65 Tier 4 Final 3 Transport instructions 38...
Page 50: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 50 Rig Layout Feeder Layout...
Page 69: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 69 Rig Layout Feeder Layout...
Page 86: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 86 Logging Signal Log Signal Log...
Page 109: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 109 Drilling DCT DCT n Parameters n Actuations...
Page 120: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 120 Rig parameters Parameters n Tramming...
Page 140: ...SmartROC D65 Tier 4 Final 6 Hydraulic systems 140...
Page 157: ...SmartROC D65 Tier 4 Final 9 Dust collector DCT 157 Dust collector...
Page 158: ...SmartROC D65 Tier 4 Final 9 Dust collector DCT 158...
Page 160: ...SmartROC D65 Tier 4 Final 10 Radiator 160 Radiator and expansion tank...
Page 170: ...SmartROC D65 Tier 4 Final 11 Diesel engine 170...
Page 182: ...SmartROC D65 Tier 4 Final 12 Compressor and air system 182...
Page 192: ...SmartROC D65 Tier 4 Final 13 Oil and fuel 192...
Page 219: ...14 Options 219...
Page 220: ...www atlascopco com 2015 12 17 No 713991051 3...