Maintenance – 2000h
99
4812268997.pdf
2017-05-10
Water tank - Cleaning
Clean the tank with water and a suitable detergent for
plastic surfaces.
1
Fig. Water tank
1.Drain cock
2
1
Fig. Cab
1. Condenser element
2. Drying filter
Close the drain cock (1), fill with water and check for
leaks.
The water tank is made of plastic
(polyethylene) and can be recycled.
Air conditioning (Optional) - Overhaul
Regular inspection and maintenance is necessary to
ensure satisfactory long-term operation.
Clean all dust from the condenser element (1) using
compressed air. Blow from above downwards.
The air jet can damage the element
flanges if it is too powerful.
Wear protective goggles when working
with compressed air.
Inspect the condenser element attachment.
Check the system hoses for chafing. Make sure that
drainage from the cooling unit is unobstructed so that
condensation does not accumulate inside the unit.
Summary of Contents for CP275 Tier II
Page 2: ......
Page 12: ...Introduction 4 4812268997 pdf 2017 05 10...
Page 18: ...Safety Optional 10 4812268997 pdf 2017 05 10...
Page 34: ...Machine description 26 4812268997 pdf 2017 05 10...
Page 36: ...Machine description 28 4812268997 pdf 2017 05 10 Location control cab...
Page 62: ...Operating instructions summary 54 4812268997 pdf 2017 05 10...
Page 64: ...Preventive maintenance 56 4812268997 pdf 2017 05 10...
Page 88: ...Maintenance 50h 80 4812268997 pdf 2017 05 10...
Page 96: ...Maintenance 250h 88 4812268997 pdf 2017 05 10...
Page 98: ...Maintenance 500h 90 4812268997 pdf 2017 05 10...
Page 112: ...Maintenance 2000h 104 4812268997 pdf 2017 05 10...
Page 118: ...Additional instruction 110 4812268997 pdf 2017 05 10...