TROUBLESHOOTING
Hydraulic attachment does not work
By
Remedy
Cause
Carrier driver
Connect the hydraulic hoses correctly (see chapter
Hydraulic
connections
)
Pressure and tank lines swapped
Carrier driver
Open the check valve
Check valve in pressure and/or tank line
closed
Carrier driver
Top up oil
Oil level in tank too low
Workshop
Replace defective coupling halves
Defective couplings blocking pressure and
tank lines
Workshop
Check electrical system of hydraulic attachment cutter
installation and remedy defects
Faults in the electrical system of the
hydraulic attachment installation
Workshop
Replace the magnet
Magnet on switch-on valve damaged
Carrier driver or Atlas Copco
Customer Center/Dealer in
your area
Check the carrier engine speed, the pump delivery and the
pressure relief valve; check the operating pressure
Operating pressure too low
Tamper plate frequency too low
By
Remedy
Cause
Carrier driver
Correct the carrier engine speed, check the operation
pressure, check the carrier mode stages
Insufficient hydraulic oil delivery volume
Carrier driver
Check the connecting fitting and tighten as required
The connecting fitting in the pressure and
tank line has come loose
Carrier driver
Open the check valve
Check valve in pressure and/or tank line
partly closed
Carrier driver
Check the oil filter and oil cooler, clean or renew them
Flow resistance on oil filter or oil cooler too
high
Workshop
Change the inside diameter: Observe the minimum inside
diameter! (see chapter
Technical specifications
)
Inside diameter of tank line too small
Atlas Copco Customer
Center/Dealer in your area
Check and lower the return pressure
Return pressure too high
Carrier driver or Atlas Copco
Customer Center/Dealer in
your area
Note:
The hydraulic oil return circuit must always be connected
directly to the tank or filter
Hydraulic oil return to the tank via a valve
section
Not allowed!
Carrier driver
Check the oil level in the hydraulic tank and top up as
required
Hydraulic oil temperature in the tank higher
than 80 °C
Workshop
Check the pressure; adjust as required; Fit new type-tested
pressure relief cartridges where necessary
Hydraulic oil pressure too low
Insufficient impact force
By
Remedy
Cause
Checking:
Atlas Copco
Customer Center/Dealer in
your area
Replacing:
by carrier
manufacturer‘s customer
service
Check the pump characteristic with a measuring device and
compare it to the original details; renew the pump if required
The pump of the hydraulic installation does
not deliver sufficient oil
41