background image

Outlet Power  

Terminals

6

INFICOLOR SMART MODULE

  

Installation

The InfiColor Smart Module is weatherproof, but must be mounted above the ground on a  
wall or post within reach of a properly grounded GFCI outlet. Do not submerse the Control 
Module or expose it to heavy rainfall. 
•  Install the Module in a well-ventilated area to ensure that the module operates within its  
    specified working temperature.

•  Verify that the Smart Module input voltage is 12 volt AC. We recommend that you use the  
    transformer provided with this unit.

Operation

The TRANS88 and TRANS150  
have a control panel featuring  
a rotary timer control switch,  
photocell and circuit  
breaker/reset button. 

The circuit breaker will turn off  
power to the lighting system in  
case of overload/power surge.  
If the circuit is tripped, inspect/repair  
the lighting system and depress the reset  
button to restore power. The photocell  
automatically turns the transformer on when it begins to get dark outside. The photocell does 
not need to be in direct sunlight; however it must have access to indirect sunlight to operate 
effectively. The timer switch provides several modes of operation. You can choose OFF, ON, 
AUTO, 4H, 6H, or 8H. 

 

   

OFF:

 Output power is off / system is off 

 

   

ON: 

Output power is on / system is on at all times

 

   

AUTO: 

Photo cell will turn the output power on at  

 

   dusk and off at dawn

 

   

4H:

 Photo cell will turn the output power on at  

 

   dusk and it will turn off after 4 hours

      

6H:

 Photo cell will turn the output power on at  

 

   dusk and it will turn off after 6 hours

 

   

8H:

 Photo cell will turn the output power on at dusk and it will turn off after 8 hours

 

Input Power Cord

Timer Control

Photocell Sensor

Circuit Breaker / Reset Button

AUTO

ON

OFF

4H

6H 8H

TRANSFORMERS - TRANS88 / TRANS150

Installation

Strip and connect the wires to the outlet power terminals  
on the back of the transformer. Loosen the screws on the  
outlet power terminals and slide the wire under the screw plate.  
Tighten the screws to secure the wire. 

Mount the Transformer in the desired location.  
The Transformer is weather-resistant and must  
be mounted above the ground on a wall or post.  
Ensure that the power cord is within reach of a properly grounded  
Ground Fault Circuit Interrupter (GFCI) equipped outlet.

After all connections to low voltage lights have been completed, plug the input power cord 
into the 120 volt GFCI outlet to complete installation. 

Summary of Contents for CCBL5

Page 1: ...Product Manual Manuel du Produit Manual del Producto 1 330 274 8317 www ATLANTICWATERGARDENS com L CCCS2 CCCS4 CCRL5 CCHL6 CCHL12 CCFL2 CCSL2 CCBL5 CCSM30X3 TRANS88 TRANS150...

Page 2: ...ten or cut the cord on Atlantic Color Changing Lights Removing the driver or cutting shortening the cord will damage the LED and void the warranty Extension cords model CCEXT20 are available to add an...

Page 3: ...of the light and thread the light into the fitting Do not use the cord to twist in the light or allow it to become twisted when tightening The spout light cannot transmit light through sweeps or arou...

Page 4: ...e assemblies are available for Hardscape Lights Remove the screws on the existing light being careful not to let the diode assembly fall as this could break the plug connecting the light to the cord L...

Page 5: ...nection diagram below for proper installation BAR LIGHT CCBL5 Installation The Bar Light is a linear light designed to wash walls falls and spillways with a wide beam angle Solid brass Bar Light inclu...

Page 6: ...The timer switch provides several modes of operation You can choose OFF ON AUTO 4H 6H or 8H OFF Output power is off system is off ON Output power is on system is on at all times AUTO Photo cell will...

Page 7: ...roup The wattage shown is the highest wattage that the light will draw rounded up to ensure Smart Module capacity is never exceeded There is also a limit to the length of any lighting run The number o...

Page 8: ...ty This limited warranty is extended solely to the original purchaser commencing from the date on the original purchase receipt and is void if any of the following apply Any round cord has been cut or...

Page 9: ...ent Individual lights within a larger system not working displaying different colors Improper connection to Splitter Smart Module Verify connections are aligned Defective 4 outlet Splitter Switch posi...

Page 10: ...ver ou de couper raccourcir le cordon endommagerait la LED et d annuler la garantie Des rallonges mod le CCEXT20 sont disponibles pour ajouter 20 6 1m de cordon suppl mentaires chaque lampe L InfiColo...

Page 11: ...re ou ne lui permettez pas de se tordre lors du serrage La Luminaire de Bec ne peut pas transmettre la lumi re par balayage ou autours des coins Il doit y avoir un chemin direct pour que la lumi re s...

Page 12: ...ED de remplacement sont disponibles pour les Luminaires de Paysage Dur Retirez les vis de la lampe existante en veillant ne pas laisser tomber l assemblage cela risquerait de casser la fiche reliant l...

Page 13: ...connexion ci dessous pour une installation correcte LE LUMINAIRE LIN AIRE CCBL5 Installation Le Luminaire Lin aire est con ue pour laver les murs les chutes et les d versoirs avec de lumi re un angle...

Page 14: ...llume la puissance de sortie au cr puscule et et il s teindra apr s 6 heures 8H La cellule photo lectrique allume la puissance de sortie au cr puscule et et il s teindra apr s 8 heures INFICOLOR SMART...

Page 15: ...Terminez le processus de vissage en remuant la connexion et en resserrant la bague filet e 2 3 fois jusqu ce qu elle soit bien en place COMMENTCALCULER LESWATTAGES ETFAIRE DES CONFIGURATIONS PERSONNA...

Page 16: ...ence a t cr e elle peut tre nomm e et sauvegard e La s quence sauvegard e sera disponible sur la page Favorites Favoris Garantie Toute l clairage Changement de Couleurs Atlantic b n ficie d une garant...

Page 17: ...quat au r partiteur 3 sorties Smart Module Inspecter le connexion aligner les cl s R partiteur 3 sorties d fectueux Changer la lampe de place avec une lampe fonctionnelle sur le m me r partiteur pour...

Page 18: ...ar el LED y anular la garant a Los cables de extensi n modelo CCEXT20 est n disponibles para agregar 20 6 1m adicionales de cable a cualquier Luz El InfiColor Smart Module es resistente a la intemper...

Page 19: ...apretar la luz o permitir que se doble al apretar La Luz de Ca o no puede transmitir luz al escanear o alrededor de las esquinas Debe haber un camino directo para que la luz sea transmitida El uso de...

Page 20: ...o Retire los tornillos de la l mpara existente teniendo cuidado de no dejar caer el conjunto ya que podr a romper el enchufe que conecta la l mpara al cable Baje el conjunto y presione el clip de bloq...

Page 21: ...rrectamente conectado a tierra Por favor siga el diagrama de conexi n a continuaci n para una instalaci n adecuada LA LUZ LINEAL CCBL5 Instalaci n La Luz Lineal est dise ada para iluminar paredes ca d...

Page 22: ...l anochecer y se apagar despu s de 8 horas INFICOLOR SMART MODULE Instalaci n El InfiColor Smart Module es resistente a la intemperie pero debe montarse por encima del suelo en una pared o poste al al...

Page 23: ...cada una de las tres zonas Las zonas se pueden enlazar y sincronizar como se desee Sume la potencia en vatios de cada luz que se puede encontrar en el Cat logo el embalaje las instrucciones o el siti...

Page 24: ...sido cortado o modificado entre el conductor y el cuerpo de la luz El cuerpo de la luz componentes del LED han sido mal utilizados o mal utilizados El cuerpo de la luz componentes del LED se han desa...

Page 25: ...ivisor est causando el problema Conexi n suelta debido a humedad o corrosi n en las conexiones Inspecciones los enchufes de conexi n r pida para saber si hay humedad corrosi n o si falta una junta Lim...

Page 26: ...26...

Page 27: ...27...

Page 28: ...1 330 274 8317 www ATLANTICWATERGARDENS com...