10
u
nit
P
laCement
• The
Sanidyne
®
Premium
is intended for indoor use only. It should be protected from liquid intrusion such as dripping
water, condensation or mist, and used only in a clean, dry location with temperature ranges between 40 °F to 95 °F.
•
Electrical power supplied to the
Sanidyne
®
Premium
must match power requirements listed on the
Sanidyne
®
Premium
.
•
The
Sanidyne
®
Premium
is intended for use in UNOCCUPIED AREAS ONLY
. Under no circumstances
should this sanitizer be permitted to operate with humans, plants, or animals present in the Operation Area
.
•
The intrusion sensors will detect movement if anyone is in the treatment area and the lamps will be switched off until fixture is
reset by pressing the
START/STOP
button on keypad on the top of the
Sanidyne
®
Premium
.
•
For maximum efficiency the
Sanidyne
®
Premium
should be located as centrally as possible, away from the corners of the
treatment area. The
Sanidyne
®
Premium
Portable Area Sanitizer is most effective when it is located in the vertical center of
the room and the ultraviolet rays are unobstructed.
UNIT OPERATION
P
re
-o
Peration
1.
Fully charge the Hand-held Remote Controller (Shown in
Figure 4
).
NOTE:
Charger provided operates on 100 volt to 240
volts 50/60Hz and has a NEMA 1-15 plug.
2. Once a location has been chosen for the
Sanidyne
®
Premium
post Laminated Warning Signs
supplied with the
Sanidyne
®
Premium
on all access doors to the area where treatment operation will take place.
It is the users responsibility to post signs, or notices for all personnel and persons in the building or facility
so that they be made aware that the Operation Area is off limits during treatment.
3.
Connect the
Sanidyne
®
Premium
to a properly grounded outlet power source which matches the power requirements
listed on the
Sanidyne
®
Premium
(See Power In location shown on
Figure 2
- Rear View of Unit)
Approved
Promate
™
Face Shields (2), are supplied with each unit.
Promate
™
Face Shield MUST be
worn prior to the next step by the operator as well as anyone else in the operation area. In addition the
operator and anyone present MUST
use protective gloves and clothing to protect skin from UV rays.
4.
Turn power on using the Power Switch located on the rear of the
Sanidyne
®
Premium
(See Power Switch location shown
on
Figure 2
- Rear View of Unit). Switch will glow
RED
when power is on. Once fixture receives power, the
RED
lights
located just below the Occupancy Sensors on the top of the fixture will glow
RED
. (See Occupancy Sensors (4-Total), shown
on
Figure 1
- Dimensional Data). This is not a warning, it indicates that the sensors are aware of your presence.
Step 5
–
Repeat until all lamps
have been installed.
Step 6
–
Once complete, reinstall
Top Cover.
Step 4
–
Using the lamp, apply
slight pressure to compress the lower
lampholder, and then pivot the lamp so
it aligns with the top lamp socket. Lamp
should appear straight when it is correctly
in place. Confirm pins are inserted and
that both ends align. As shown above,
adjust each lamp socket if there is any gap
between the lamp base and lamp socket.