Atlantic Ultraviolet Sanidyne PREMIUM Owner'S Manual Download Page 5

5

PRODUCT APPLICATIONS 

C

onstruCtion

The 

Sanidyne

®

 

Premium

 Germicidal Ultraviolet Portable Area Sanitizer consists of:

•  STER-L-RAY

®

 

Amalgam Germicidal Ultraviolet Lamps:

 Deliver ultraviolet energy at the specific wavelength of 254 

nanometers (nm). This wavelength is highly effective against microbes including virus, bacteria and mold spores. Germicidal 

ultraviolet rays are harmful to eyes and skin, avoid exposure of direct or reflected germicidal ultraviolet rays without approved 

ultraviolet blocking face shield and protective covering (such as gloves, long sleeves with no gaps between cuff and gloves).

• 

Audible Exit Warning Alarm:

 To alert area that the lamps will be powered on in one minute and thirty seconds after the start 

button is pressed or to indicate intruder is in Operation Area.

• 

Elapsed Time Indicator:

 A non-resettable display of the operating hours. Useful for scheduling and recording maintenance 

and lamp replacement.

• 

Hand-Held Remote Controller:

 Provides easy operation of 

Sanidyne

®

 

Premium

 from a safe distance, displays lamp 

operation, controls treatment times and alerts operator with an audible alarm if an intruder enters Operation Area.

•  Keypad Controller:

 Provides easy operation of 

Sanidyne

®

 

Premium

 and allows the operator a period of time (one minute 

and thirty seconds) to leave the Operation Area before treatment begins.

•  Intruder Sensors:

 Delay treatment if the Operation Area is inhabited. Additionally if sensors detect an intruder with less than 

30 seconds left before lamps operate, the countdown time will automatically restore back to 30 seconds until area is cleared.

•  Four Wheels with Locking Casters:

 Make moving 

Sanidyne

®

 

Premium

 easily accomplished for location changes.

•  Power Cord:

 For 120v AC 50/60Hz single-phase standard household current, a NEMA 5-20, three-prong plug is provided for 

a properly grounded outlet. (Consult factory for other plug types).

• 

Stainless Steel Lamp Guard Assembly:

 Protects lamps from damage during normal operation.

•  Stainless Steel Construction

: All electronics and wiring are housed in an enclosure constructed of stainless steel, providing 

strength and durability in order to withstand most harsh environments.

•  Cooling Fans:

 Circulate cool, clean air to ensure all electronics are operating at optimum temperatures.

•  Sanidyne

®

 

Premium

 will operate at 120v 50/60Hz.

P

rinCiPle

 

of

 o

Peration

The

 

Sanidyne

®

 

Premium

 design has been carefully conceived to provide direct germicidal ultraviolet exposure for air and 

surface disinfection in 

unoccupied

 areas to disinfect and prevent areas and surfaces from microorganisms. The ultraviolet 

disinfection dosage is a function of time and the intensity, of the ultraviolet radiation to which the air and surrounding surfaces 

 

are exposed.

NOTE:

 The 

Sanidyne

®

 

Premium

 should be used as a supplement to your facility’s cleaning and disinfection protocols, not as a 

replacement.  Follow your facility’s cleaning and disinfection protocols before using the 

Sanidyne

®

 

Premium

No special room preparation is required prior to treating a room or area with the 

Sanidyne

®

 

Premium 

 however, target 

surfaces must be directly exposed to the UV rays. These rays will not penetrate materials like cloth, paper or ordinary glass, 

therefore, it is important to remove items from the direct line of sight that would block or shield the rays from other surfaces. The 

Sanidyne

®

 

Premium

 does not generate any harmful byproducts, nor does it leave any residual substances.

It is the user’s responsibility to determine and validate the suitability of the equipment for use in system 

or process. No warranty or representation is made by the manufacturer with respect to suitability or performance of this 

equipment or to the results that may be expected from its use. 

Indoor Use Only – The equipment must be sheltered from exposure to the elements and extremes in 

temperature. Temperature range: 40 °F to 95 °F. The user should periodically inspect, clean as necessary and confirm the 

presence and good legibility of the Product safety labels. Contact the factory for replacement labels in the event that any of 

the labeling is missing or illegible.

The UV Treatment Results achieved are subject to variations in application conditions, it is recommended 

that culture tests be performed to confirm desired outcomes.

l

imitations

•  Safety procedures 

MUST

 be implemented to prevent ultraviolet exposure of occupants to direct or reflected ultraviolet rays. 

Exposure to germicidal ultraviolet rays will result in the irritation of the eyes and reddening of the skin.

• 

Personal protection equipment is required when entering the irradiated space with the germicidal 

lamp(s) operating. Personal protection equipment includes skin and eye protection such as gloves, long 

sleeves with no gaps between cuff and gloves, and an ultraviolet blocking face shield (included with the 

purchase of the 

Sanidyne

®

 

Premium

).

Summary of Contents for Sanidyne PREMIUM

Page 1: ...ctions Save These Instructions UV Ultraviolet Radiation Protect eyes and skin from direct and reflected radiation DANGER Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 37...

Page 2: ...16 MAINTENANCE LOG 17 19 USER ASSISTANCE 20 Patent Notice 20 WARRANTY PRODUCT REGISTRATION 20 These instructions generally describe the installation operation and maintenance of the Sanidyne Premium...

Page 3: ...3 Read and follow all notices and warnings on the sanitizer 14 SAVE THESE INSTRUCTIONS SAFETY WARNINGS All personnel should be alerted to the potential hazards indicated by the product safety labeling...

Page 4: ...or process No warranty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that may be expected from its use The user should p...

Page 5: ...le of Operation The Sanidyne Premium design has been carefully conceived to provide direct germicidal ultraviolet exposure for air and surface disinfection in unoccupied areas to disinfect and prevent...

Page 6: ...nspect all packing materials to prevent the loss of accessories spare parts or instructions Do not discard packing materials until Sanidyne Premium is assembled checked and confirmed The Sanidyne Prem...

Page 7: ...tart Stop Button Begins treatment time countdown also used to restart unit after an intruder is sensed in Operating Area 5 Power Indicator Glows RED when power is applied to unit and will flash during...

Page 8: ...te and 30 seconds to exit area b The words LEAVE AREA appear on the lower status bar c Alarm on unit begins to sound d The word PrEP flashes on the Keypad during the Countdown Time when Treatment Time...

Page 9: ...ler 13 ON OFF Button Turns the power to the device on or off and can be used to restart the device To turn on the device this button must be pushed in and held for 2 seconds If the device is on the Ho...

Page 10: ...ment operation will take place It is the users responsibility to post signs or notices for all personnel and persons in the building or facility so that they be made aware that the Operation Area is o...

Page 11: ...than 30 seconds remain on the countdown time the Sanidyne Premium will automatically reset giving 30 seconds more to leave the Operation Area Occupancy Sensors do not protect the entire Operation Area...

Page 12: ...n the display or at the Sanidyne Premiumby pressing the START STOP on the Keypad If the Alarm is turned off at the Sanidyne Premiumthe operator can reset the fixture by pressing the START STOP button...

Page 13: ...r table etc 2 Measure the longest distance from the Sanidyne Premium to the farthest wall Use this length to compare to the Distance From Fixtures Time Minutes shown on Figure 5 below 3 For example if...

Page 14: ...D AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN NOTE STER L RAY lamps used in the Sanidyne Premium have ArmorLiteTM Safety Shield which is a protective co...

Page 15: ...Surelite Ballast not operating Disconnect the fixture from utility power then replace ballast Sanidyne Premium fails to shut off Microprocessor assembly faulty Wearing protective clothing and face shi...

Page 16: ...side and can be placed in supplied wall holder Uses 1 AAA battery 6 UV C Dosimeter Card 00 0373 Contains a patented colorimetric indicator that changes color at 25 50 and 100 mJ cm2 to visibly confirm...

Page 17: ...17 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Page 18: ...18 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Page 19: ...19 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Page 20: ...including warranties of merchantability and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the cus...