background image

11

Quartz Sleeve Installation, Cleaning, or Replacement

Step 6 - Remove Quartz Sleeve

Step 5 - Remove Washer & O-Ring 

 

From Each End

Step 4 - Remove Gland Nut From Each End

Figure 5 – BIO-1.5 & BIO-3.0  120v 50/60Hz (ballast no. 10-0518A)

IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING 

SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.

1. 

  

  Disconnect power to water purifier.

• 

For 120v 50/60Hz version using ballast no. 10-0518A or 230v 50/60hz version using ballast no. 10-0514A, remove 

the ground connector from the chamber, and go to the next step.

2. 

Shut off water supply to water purifier via inlet and outlet shut off valves and drain chamber.

3. 

Follow the steps in 

“Lamp Installation or Replacement”

 to remove lamp. 

  Lamp and quartz sleeve are easily damaged. Exercise care when handling.

4. 

Unscrew static gland nuts from each end of the chamber. Avoid striking quartz sleeve with static gland nut.

5. 

Remove Teflon

®

 washer and O-Ring from both ends of quartz sleeve. Teflon

®

 washer will sometimes remain within the static 

gland nut. If so, remove Teflon

®

 washer from static gland nut before proceeding.

6. 

Carefully remove quartz sleeve from chamber. 

NOTE: It is advisable to support the quartz sleeve on the opposite end with 

your finger so that it does not drop to the bottom of the chamber as it slides into the chamber.

7. 

Once the quartz sleeve is removed, clean with alcohol or a mild, non-abrasive detergent. Stubborn stains usually can be 

removed with a dilute hydrochloric acid. 

NOTE:

 

Follow all manufacturer’s instructions and precautions 

when handling chemicals.

8. 

Reassemble in reverse order. Make sure the quartz sleeve protrudes an equal distance past each threaded nipple. Be sure 

O-Rings are placed on quartz sleeve before Teflon

®

 washer.

9. 

Tighten static gland nuts firmly by hand only, 

DO NOT USE HAND TOOLS

. Tightening with hand tools is likely to cause 

quartz sleeve to break.

10. 

Slowly

 restore water supply to water purifier and check for leaks.

11. 

If no leaks occur, reinstall lamp, following the steps in 

“Lamp Installation or Replacement”

 section. 

  Germicidal ultraviolet rays are harmful to eyes and skin. Do not restore power to water purifier until lamp 

and both 

EASY-OFF

TM

 End Caps have been properly reinstalled. 

Summary of Contents for Bio-Logic BIO 1.5

Page 1: ...Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 375 Marcus Boulevard Hauppauge NY 11788 631 273 0500 Fax 631 273 0771 Email Sales AtlanticUV com Shop Products at AtlanticU...

Page 2: ...Patent Notice 16 WARRANTY PRODUCT REGISTRATION 16 These instructions generally describe the installation operation and maintenance of the Bio Logic Ultraviolet Water Purifiers Models BIO 1 5 and BIO...

Page 3: ...TLY hazardous situation which if not avoided WILL result in death or serious injury To guard against injury basic safety precautions should be observed including the following 1 Read and follow ALL sa...

Page 4: ...ual indication of germicidal lamp operation Water leaving the purifier is instantly ready for use no further contact time is required Limitation of Use The water purifier is intended for the use with...

Page 5: ...er should always be located closest to the point of use This reduces the chance of the purified water being re contaminated by bacteria in the water distribution system after the water purifier 6 As w...

Page 6: ...6 Recommended Installation Figure 2 Recommended Installation...

Page 7: ...ter be installed in line prior to the water purifier The sediment filter will stop or trap any particulates from entering the water purifier Particulates may cause damage to the quartz sleeve as well...

Page 8: ...sensor is capable of operating an optional audio alarm and or solenoid valve 13 Promate Audio Alarm Activated by the Ultraviolet Monitor or Safety Sensor alerts the user to any malfunction detected 1...

Page 9: ...actory with questions Inspection 1 Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation An LED indicator light located on the ballast provides visual indicatio...

Page 10: ...mber While holding lamp end remove lamp socket from exposed lamp end 4 Carefully withdraw lamp from chamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleev...

Page 11: ...hin the static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the oppos...

Page 12: ...o remove all quartz fragments from the interior of the chamber 8 Carefully discard all pieces of the broken quartz sleeve 9 Align the end of the quartz sleeve with the gland fitting of the chamber 10...

Page 13: ...he Maintenance section Low input voltage Verify input voltage to purifier Change in water quality Have water tested to confirm that it does not exceed maximum recommended concentration levels for use...

Page 14: ...special input power requirements Table 5 Optional Accessories Optional Accessories Available for SENTRY Safety Sensor BIO 1 5 BIO 3 0 Promate Time Delay Mechanism BIO 1 5 BIO 3 0 Promate Elapsed Time...

Page 15: ...5 1366 R 05 1370 R 4 Static Gland Nut 2 25 1492D 25 1492D 5 Teflon Washer 2 25 3023A 25 3023A 6 Rubber O Ring Quartz Sleeve 2 00 1023A 00 1023A 7 CRYSTAL CLEAR Quartz Sleeve 1 15 1700A 15 1701A 8 Cham...

Page 16: ...bility and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the customer or to any person for injury...

Reviews: