Installation: BIO-1.5 and BIO-3.0 using ballast no.10-0518A 120v 50/60Hz 

and using ballast no.10-0514A 230v 50/60Hz

IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING 

SAFETY EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.

1. 

Remove water purifier from shipping carton. Inspect water purifier, power cord and plug for damage. Do not operate if there 

is any damage to the purifier, power cord or plug. All models, of the 

Bio-Logic

®

 

line of water purifiers, are shipped with the 

lamps packed separately. Keep the lamp aside for installation once the purifier has been properly installed.

2. 

Units occasionally experience damage in shipment due to the fragility of the quartz sleeve.  It is therefore recommended to 

inspect the water purifier for damage to the quartz sleeve after it has been removed from the shipping carton. Each end of the 

unit as well as the inlet and outlet should be viewed to see if the quartz sleeve has experienced damage. If the quartz sleeve 

shows signs of damage it should be replaced before the purifier is pressurized.  See 

“Quartz Sleeve Installation, Cleaning, or 

Replacement”

 in the 

“Maintenance”

 section on 

Page 11

 for the proper method of replacing the quartz sleeve in your water 

purifier.

3. 

The water purifier should be mounted horizontally on a flat dry surface. The purifier should not be solely supported by its 

plumbing connections. Secure the water purifier using the mounting clips. 

4. 

The water purifier 

MUST

 be connected to the cold water line only. Inlet water temperature should not exceed 100

F.

5. 

Installation requires a 5-micron sediment filter be installed, in line, prior to the water purifier. The sediment filter will stop or 

trap any particulates from entering the water purifier. Particulates may cause damage to the quartz sleeve, as well as interfere 

with the purifier’s ability to disinfect the water. The sediment filter may also help to reduce the amount of routine cleanings of 

the quartz sleeve.

6. 

Shut off valves should be installed on both the inlet and outlet sides of the water purifier. 

The use of bypass valves is not 

recommended.

 The shut off valves allow the purifier to be isolated from the water supply, which is required when removing 

the quartz sleeve.

7. 

Unions should be installed on both the inlet and outlet of the water purifier; this will allow easy removal of the water purifier 

from the plumbing, if required. Apply Teflon

®

 tape to threads of inlet and outlet ports to ensure a tight seal.

8. 

When all plumbing connections are complete, allow water to enter the water purifier at a low flow rate, until the purifier is full. 

NOTE:

 Close the purifier outlet valve to pressurize the chamber. 

With the purifier pressurized, it should be checked for 

leaks. Once it is determined that there are no leaks, the inlet valve can be fully opened.

Figure 3 – 120v and 230v 50/60Hz (ballast no. 10-0518A and 10-514A)

9. 

Unpack the lamp and ballast. While holding lamp end, carefully push lamp socket on. Carefully slide lamp straight into the 

quartz sleeve, without angling. Push the End Cap on, over the static gland nut. Attach the ground connector to the grounding 

tab of the chamber with included hardware (see photo on 

Page 8

).

To ensure proper operation and safety of the purifier, your unit must be connected to a known good ground.

Lamp and quartz sleeve are easily damaged. Exercise care when handling.

“Installation” continued on next page

Summary of Contents for Bio-Logic BIO 1.5

Page 1: ...Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 375 Marcus Boulevard Hauppauge NY 11788 631 273 0500 Fax 631 273 0771 Email Sales AtlanticUV com Shop Products at AtlanticU...

Page 2: ...Patent Notice 16 WARRANTY PRODUCT REGISTRATION 16 These instructions generally describe the installation operation and maintenance of the Bio Logic Ultraviolet Water Purifiers Models BIO 1 5 and BIO...

Page 3: ...TLY hazardous situation which if not avoided WILL result in death or serious injury To guard against injury basic safety precautions should be observed including the following 1 Read and follow ALL sa...

Page 4: ...ual indication of germicidal lamp operation Water leaving the purifier is instantly ready for use no further contact time is required Limitation of Use The water purifier is intended for the use with...

Page 5: ...er should always be located closest to the point of use This reduces the chance of the purified water being re contaminated by bacteria in the water distribution system after the water purifier 6 As w...

Page 6: ...6 Recommended Installation Figure 2 Recommended Installation...

Page 7: ...ter be installed in line prior to the water purifier The sediment filter will stop or trap any particulates from entering the water purifier Particulates may cause damage to the quartz sleeve as well...

Page 8: ...sensor is capable of operating an optional audio alarm and or solenoid valve 13 Promate Audio Alarm Activated by the Ultraviolet Monitor or Safety Sensor alerts the user to any malfunction detected 1...

Page 9: ...actory with questions Inspection 1 Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation An LED indicator light located on the ballast provides visual indicatio...

Page 10: ...mber While holding lamp end remove lamp socket from exposed lamp end 4 Carefully withdraw lamp from chamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleev...

Page 11: ...hin the static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the oppos...

Page 12: ...o remove all quartz fragments from the interior of the chamber 8 Carefully discard all pieces of the broken quartz sleeve 9 Align the end of the quartz sleeve with the gland fitting of the chamber 10...

Page 13: ...he Maintenance section Low input voltage Verify input voltage to purifier Change in water quality Have water tested to confirm that it does not exceed maximum recommended concentration levels for use...

Page 14: ...special input power requirements Table 5 Optional Accessories Optional Accessories Available for SENTRY Safety Sensor BIO 1 5 BIO 3 0 Promate Time Delay Mechanism BIO 1 5 BIO 3 0 Promate Elapsed Time...

Page 15: ...5 1366 R 05 1370 R 4 Static Gland Nut 2 25 1492D 25 1492D 5 Teflon Washer 2 25 3023A 25 3023A 6 Rubber O Ring Quartz Sleeve 2 00 1023A 00 1023A 7 CRYSTAL CLEAR Quartz Sleeve 1 15 1700A 15 1701A 8 Cham...

Page 16: ...bility and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the customer or to any person for injury...

Reviews: