TROUBLESHOOTING

 

  

Always disconnect power to the water purifier before performing any service or maintenance.

IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel.

Table 3 – Troubleshooting

Problem

Possible Cause

Corrective Action

Purifier not operating

No electrical power

Verify that the purifier is connected to a live power source.

Water leaking from purifier

Cracked or broken quartz sleeve

Shut down purifier, drain, and replace quartz sleeve. See 

“Quartz Sleeve 

Installation, Cleaning, or Replacement” 

or 

“Replacement of Broken 

Quartz Sleeve”

 in the

 “Maintenance”

 section.

Quartz sleeve sealing O-Ring(s)

 

worn, damaged

Shut down purifier, drain, and  remove static gland nut, replace sealing 

O-Ring. See 

“Quartz Sleeve Installation, Cleaning, or Replacement”

 

in the

 “Maintenance”

 section.

Poor, or loose, connections or fittings

Tighten suspect connection or fitting; or shut down purifier, drain, 

and remove fitting or connection. Clean threads; reapply thread 

sealing tape and reinstall.

Poor purifier disinfection performance

Quartz sleeve fouled

Clean quartz sleeve, see 

“Quartz Sleeve Installation, Cleaning, or 

Replacement”

 in the 

“Maintenance”

 Section.

STER-L-RAY

®

 

Germicidal Lamp 

output depreciating

Replace lamp, as it nears its end of life 

(EOL)

. See 

“Lamp Installation 

or Replacement”

 in the 

“Maintenance”

 section.

STER-L-RAY

®

 

Germicidal Lamp

 

not functioning

Replace lamp. See 

“Lamp Installation or Replacement”

 in the 

“Maintenance”

 section.

Low input voltage

Verify input voltage to purifier.

Change in water quality

Have water tested to confirm that it does not exceed maximum 

recommended concentration levels for use with this purifier.

Ballast No. 10-0518A and 10-0514A have Lamp-out Protection

 

If power is applied to the ballast without a lamp connected to the circuit or if the lamp fails, the ballast’s lamp-out protection 

will prevent the ballast from operating, and a red LED light will illuminate and audio alarm will sound. 

To reset: disconnect the 

ballast from power and reconnect or replace the lamp.

 The ballast must remain disconnected from power for (2) minutes to 

reset. After 2 minutes, restore input power. Ballast should resume proper operation.

  

The equipment that this ballast is used with requires connection to a known good ground. It is the User’s 

responsibility to ensure that their equipment is properly grounded in compliance with the National Electrical Code and any 

applicable local codes. Equipment wiring and hook up should be performed by a qualified, licensed electrician. Failure to comply 

with this requirement could result in serious injury or death.

Disposal of Mercury Added Lamps

Germicidal ultraviolet lamps, like standard fluorescent lamps contain small amounts of mercury. Mercury added 

lamps should not be placed in the trash. Dispose of properly. For further information regarding the disposal and 

recycling of lamps containing mercury, along with Federal and State requirements visit LampRecycle.org. For more 

information on 

STER-L-RAY

®

 

Germicidal Ultraviolet Lamps, visit AtlanticUltraviolet.com or Ultraviolet.com.

Summary of Contents for Bio-Logic BIO 1.5

Page 1: ...Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 375 Marcus Boulevard Hauppauge NY 11788 631 273 0500 Fax 631 273 0771 Email Sales AtlanticUV com Shop Products at AtlanticU...

Page 2: ...Patent Notice 16 WARRANTY PRODUCT REGISTRATION 16 These instructions generally describe the installation operation and maintenance of the Bio Logic Ultraviolet Water Purifiers Models BIO 1 5 and BIO...

Page 3: ...TLY hazardous situation which if not avoided WILL result in death or serious injury To guard against injury basic safety precautions should be observed including the following 1 Read and follow ALL sa...

Page 4: ...ual indication of germicidal lamp operation Water leaving the purifier is instantly ready for use no further contact time is required Limitation of Use The water purifier is intended for the use with...

Page 5: ...er should always be located closest to the point of use This reduces the chance of the purified water being re contaminated by bacteria in the water distribution system after the water purifier 6 As w...

Page 6: ...6 Recommended Installation Figure 2 Recommended Installation...

Page 7: ...ter be installed in line prior to the water purifier The sediment filter will stop or trap any particulates from entering the water purifier Particulates may cause damage to the quartz sleeve as well...

Page 8: ...sensor is capable of operating an optional audio alarm and or solenoid valve 13 Promate Audio Alarm Activated by the Ultraviolet Monitor or Safety Sensor alerts the user to any malfunction detected 1...

Page 9: ...actory with questions Inspection 1 Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation An LED indicator light located on the ballast provides visual indicatio...

Page 10: ...mber While holding lamp end remove lamp socket from exposed lamp end 4 Carefully withdraw lamp from chamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleev...

Page 11: ...hin the static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the oppos...

Page 12: ...o remove all quartz fragments from the interior of the chamber 8 Carefully discard all pieces of the broken quartz sleeve 9 Align the end of the quartz sleeve with the gland fitting of the chamber 10...

Page 13: ...he Maintenance section Low input voltage Verify input voltage to purifier Change in water quality Have water tested to confirm that it does not exceed maximum recommended concentration levels for use...

Page 14: ...special input power requirements Table 5 Optional Accessories Optional Accessories Available for SENTRY Safety Sensor BIO 1 5 BIO 3 0 Promate Time Delay Mechanism BIO 1 5 BIO 3 0 Promate Elapsed Time...

Page 15: ...5 1366 R 05 1370 R 4 Static Gland Nut 2 25 1492D 25 1492D 5 Teflon Washer 2 25 3023A 25 3023A 6 Rubber O Ring Quartz Sleeve 2 00 1023A 00 1023A 7 CRYSTAL CLEAR Quartz Sleeve 1 15 1700A 15 1701A 8 Cham...

Page 16: ...bility and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the customer or to any person for injury...

Reviews: