Replacement of Broken Quartz Sleeve

IN ORDER TO PERFORM THIS TASK, BE SURE TO WEAR THE FOLLOWING SAFETY 

EQUIPMENT: SAFETY GLASSES OR A FACE SHIELD, AS WELL AS GLOVES.

Broken Quartz is SHARP. It is recommended that protective glasses and gloves are worn when handling.

1. 

  

  Disconnect power to water purifier.

• 

For 120v 50/60Hz version using ballast no. 10-0518A or 230v 50/60hz version using ballast no. 10-0514A, remove 

the ground connector from the chamber, and go to the next step.

2. 

Shut off water supply to water purifier via inlet and outlet shut off valves and drain chamber.

3. 

Follow the steps in 

“Lamp Installation or Replacement”

 to remove lamp.

4. 

Unscrew static gland nuts from each end of the chamber. Avoid striking quartz sleeve with static gland nut.

5. 

Remove Teflon

®

 washer and O-Ring from both ends of quartz sleeve. Teflon

®

 washer will some times remain within the static 

gland nut. If so, remove Teflon

®

 washer from static gland nut before proceeding.

6. 

Carefully

 remove as much of the broken quartz sleeve as possible, from each end of the chamber.

7. 

To remove fragments of quartz sleeve, hold the purifier vertically and shake. The quartz fragments will break and drop out 

of the purifier through the gland fitting. Flush water through chamber being careful to remove all quartz fragments from the 

interior of the chamber.

8. 

Carefully discard all pieces of the broken quartz sleeve.

9. 

Align the end of the quartz sleeve with the gland fitting of the chamber.

10. 

Carefully slide the quartz sleeve into the chamber, guiding it through the gland fitting. 

NOTE: 

Use care to keep the quartz 

sleeve parallel to the chamber, angling the quartz sleeve in any direction could result in the breakage of the quartz sleeve.

11. 

As the quartz sleeve nears the far end of the chamber, support the quartz sleeve by inserting your finger through the far end 

gland fitting and into the quartz sleeve. This will minimize the possibility of breaking the quartz sleeve as it passes through the 

gland fitting.

12. 

Center the quartz sleeve in the chamber, making sure the quartz sleeve protrudes an equal distance past each threaded gland 

fitting, of the chamber.

13. 

Re-install O-Rings, Teflon

®

 washers, and static gland nuts. Be sure O-Rings are placed on quartz sleeve before Teflon

® 

washer. 

Tighten static gland nuts firmly by hand only, 

DO NOT USE HAND TOOLS.

 Tightening with hand tools is likely to cause 

quartz sleeve to break.

14. 

When all connections are complete allow water to enter the water purifier at a low flow rate until the purifier is pressurized. 

With the purifier pressurized, it should be checked for leaks.

15. 

If no leaks occur, reinstall lamp, following the steps in 

“Lamp Installation or Replacement”

 section.

Figure 6 – Chamber Head Removal

Summary of Contents for Bio-Logic BIO 1.5

Page 1: ...Manufacturers Engineers Sales Service Germicidal Ultraviolet Equipment Lamps 375 Marcus Boulevard Hauppauge NY 11788 631 273 0500 Fax 631 273 0771 Email Sales AtlanticUV com Shop Products at AtlanticU...

Page 2: ...Patent Notice 16 WARRANTY PRODUCT REGISTRATION 16 These instructions generally describe the installation operation and maintenance of the Bio Logic Ultraviolet Water Purifiers Models BIO 1 5 and BIO...

Page 3: ...TLY hazardous situation which if not avoided WILL result in death or serious injury To guard against injury basic safety precautions should be observed including the following 1 Read and follow ALL sa...

Page 4: ...ual indication of germicidal lamp operation Water leaving the purifier is instantly ready for use no further contact time is required Limitation of Use The water purifier is intended for the use with...

Page 5: ...er should always be located closest to the point of use This reduces the chance of the purified water being re contaminated by bacteria in the water distribution system after the water purifier 6 As w...

Page 6: ...6 Recommended Installation Figure 2 Recommended Installation...

Page 7: ...ter be installed in line prior to the water purifier The sediment filter will stop or trap any particulates from entering the water purifier Particulates may cause damage to the quartz sleeve as well...

Page 8: ...sensor is capable of operating an optional audio alarm and or solenoid valve 13 Promate Audio Alarm Activated by the Ultraviolet Monitor or Safety Sensor alerts the user to any malfunction detected 1...

Page 9: ...actory with questions Inspection 1 Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation An LED indicator light located on the ballast provides visual indicatio...

Page 10: ...mber While holding lamp end remove lamp socket from exposed lamp end 4 Carefully withdraw lamp from chamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleev...

Page 11: ...hin the static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the oppos...

Page 12: ...o remove all quartz fragments from the interior of the chamber 8 Carefully discard all pieces of the broken quartz sleeve 9 Align the end of the quartz sleeve with the gland fitting of the chamber 10...

Page 13: ...he Maintenance section Low input voltage Verify input voltage to purifier Change in water quality Have water tested to confirm that it does not exceed maximum recommended concentration levels for use...

Page 14: ...special input power requirements Table 5 Optional Accessories Optional Accessories Available for SENTRY Safety Sensor BIO 1 5 BIO 3 0 Promate Time Delay Mechanism BIO 1 5 BIO 3 0 Promate Elapsed Time...

Page 15: ...5 1366 R 05 1370 R 4 Static Gland Nut 2 25 1492D 25 1492D 5 Teflon Washer 2 25 3023A 25 3023A 6 Rubber O Ring Quartz Sleeve 2 00 1023A 00 1023A 7 CRYSTAL CLEAR Quartz Sleeve 1 15 1700A 15 1701A 8 Cham...

Page 16: ...bility and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the customer or to any person for injury...

Reviews: