The IB2S-A Active Series monitor is configured and controlled
via the supplied remote control panel which has an LCD
display with two rows of up to 16 characters each, plus four
push buttons and a rotary control.
The top push button accesses the configuration menu, with
a back button to exit. The preset button accesses the user
preset facilities, and the mute button mutes the loudspeakers.
The menu displays are navigated using the rotary control
wheel which has a push-button action that is used to select
the currently displayed parameter.
The generic display is shown below. The lower row identifies
the loudspeakers connected in the system (Left, Centre,
Right, Left Surround, Right Surround, LFE1, LFE2), together with
the current volume setting (±00.0dB in the example below).
The upper row indicates the current function (Volume in this
example), and the asterix symbols warn of a clipped loud-
speaker channel.
*
*
*
*
*
*
*
V
o
l
u
m
e
L
C
R
L
s
R
s
1
2
+
0
0
.
0
d
B
1 Standby Mode
Standby mode is activated either on start-up, when power-off is pressed in the main menu, or when a trig-
ger signal is lost if the Trigger ON mode is enabled.
1.1 Trigger-OFF
When the 12V trigger mode is set to OFF in the main menu (see 3.1.3) the default standby mode display will
look like this (Note: the backlight will be off, and there is no sub-menu):
Z
z
z
Actions:
Buttons
:
MENU/BACK/PRESETS/MUTE/SELECT: The System turns on and the
default display appears (see 2).
Rotary:
UP/DOWN: System turns on, and the default display appears (see 2).
Clip
:
Can’t be sent because of standby mode.
Trigger
:
Can’t be sent because of trigger-off mode.