Before each fault clearance:
−
switch off device
−
pull out main plug
Problem Possible
cause
Remedy
Logs are not being split
properly
(insufficient splitting
performance).
⇒
The log is not positioned correctly.
⇒
The log exceeds the maximum dimensions or
the wood is too hard for the performance of
the machine.
⇒
Splitting blade does not split log.
⇒
Hydraulic pressure too low.
⇒
Release rods bent (hydraulic tappet not quite
pressed in).
⇒
Incorrect connecting lead (longer than 10 m or
too small cable cross-section).
⇒
Reposition the log correctly.
⇒
Cut the log to the required dimensions.
⇒
Sharpen splitting blade, check for burrs or notches.
⇒
Check the oil level and add more oil if necessary.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
⇒
Arrange for manufacturer or authorised company to
adjust the rods.
⇒
Use the correct connecting lead.
Splitting column moves
unsteadily or with strong
vibrations.
⇒
Air in the circuit.
⇒
Splitting column not sufficiently lubricated or
oiled.
⇒
Check the oil level and add more oil if necessary.
⇒
Lubricate splitting column or oil with environmentally
friendly spray oil.
If the problem cannot be rectified, refer to the
manufacturer or other approved service centre.
Splitting column does not
move in.
⇒
Hydraulic pump defective.
⇒
To correct the problem, refer to the manufacturer or
other approved service centre.
Motor starts, but splitting
column does not move in.
⇒
Motor turns in wrong direction
⇒
Check the motor direction
Threephase: adjust the motor direction
Motor will not start.
⇒
No electrical power.
⇒
2-phase mode in threephase motor.
⇒
Connection cable defective.
⇒
Electric motor defective.
⇒
Check the fuse.
⇒
Have fuse and lead checked by qualified electrician.
⇒
Replace the connection cable or have it checked by an
electrician.
⇒
To correct the problem, refer to the manufacturer or
other approved service centre.