26
When should I change the oil?
The first oil change should be carried out after 50 operating
hours, and then every 500 operating hours.
Two persons are required for this.
Changing the oil:
1.
The splitting column must be in run-in state.
2.
Now remove the dipstick.
3.
Place a container under the log splitter to catch the old oil.
The container should have a capacity of at least 6 litres.
4.
Screw off the drain plug to allow the oil to flow out.
5.
Insert the seal and drain plug again.
6.
Pour in the new hydraulic oil using a clean funnel.
7.
Clean the dipstick and the oil seal.
8.
Check the oil seal and replace it if it is damaged in any way.
9.
Replace the dipstick.
Dispose of the old oil properly (local oil disposal point). The
old oil must not be poured into the ground or drainage
system, or mixed with other waste.
L
Hydraulic oil
We recommend the following hydraulic oils for the hydraulic
cylinder:
¾
Shell Tellus T 22
¾
Aral Vitam Gf 22
¾
BP Energol HLP 22
¾
Mobil DTE 11
¾
or equivalent
Do not use any other types of oil. The use of any other type
of oil will adversely affect the operation of the log splitter.
T
T
e
e
c
c
h
h
n
n
i
i
c
c
a
a
l
l
d
d
a
a
t
t
a
a
Model / Type
ASP 12 TS
Year of construction
see last page
Splitting force
120 kN (12 t)
Log length
max. 1350 mm
Log diameter
min. 80 mm – max. 450 mm
Stroke
≈
550 mm
Feed speed
approx. 0.05 m/sek.
Return speed
approx. 0.22 m/sek.
Hydraulic oil (max.)
6 litres
Hydraulic pressure
24.5 MPa (245 bar)
Electric motor performance (power consumption)
P
1
3.5 kW S6-40%
Power supply
400 V / 3N~+PE 50 Hz, 16 A
Dimensions
length 910 x width 620 x height 1610 mm
Weight approx.
175