CLEANING THE VALVE BLOCK
Separate the air pipes (H) from the valve block
(V).
Clean the valve block (V) using compressed air.
The valve block may need to be replaced.
Clean the silencers (S). If these are damaged,
they must be replaced.
SETTING THE MOUNTING HEAD
Loosen the fixing screw (1) on the mounting
head
The angle of the mounting head to the rim can
be set by tightening and/or loosening both
grub screws (2)
The bead guide (4) projects approx. 6-7 mm
over the rim flange. The approach roller (3)
contacts the rim flange.
After setting, ensure that both grub screws (2)
and the fixing screw (1) are secured again.
CHECKING AND REFILLING THE GEAR OIL
Turn the clamping plate to a position from
which it is easy to access the oil filler neck
Now remove the protective cover
Insert a flexible and transparent hose into the
opening and stop when the hose contacts the
base of the gear unit.
Now, hold the end of the hose shut so that no
more air can get in.
Next, remove the hose. The oil level must be at
least 25 mm.
If necessary, refill with the required amount of
oil.
3
Summary of Contents for 80424200937
Page 3: ...BEDIENUNGSANLEITUNG ATH M72Z Plus ...
Page 59: ...OPERATING INSTRUCTIONS ATH M72Z Plus ...
Page 115: ...MANUEL D UTILISATION ATH M72Z Plus ...
Page 171: ...NÁVOD K OBSLUZE ATH M72Z Plus ...
Page 227: ...MANUAL DE INSTRUCCIONES ATH M72Z Plus ...
Page 283: ...BEDIENINGSHANDLEIDING ATH M72Z Plus ...
Page 339: ...INSTRUKCJA OBŁSUGI ATH M72Z Plus ...
Page 395: ...NÁVOD NA OBSLUHU ATH M72Z Plus ...