Hardware installation & connection
3
© 2019, ATEÏS, member of PAX ProAV Group
To identify the connection among the secondary units, each secondary unit has an unique ID.
And the ID must be set orderly based on the Digi-link connection. For example, if the ID of BTQ-
VM8 controller is 1:
1
, then the ID of the first connected BTQ-SL8 unit on BTQ-VM8 will be 1:
2
,
and 1:
3
for the second BTQ-SL8 unit. See
GLOBAL-NET
Connect the BTQ-VM4/8 controller and SG8 secondary unit together through A, B port via global-net.
Device ID
The BTQ-SL8, BTQ-SG8 secondary units and DPM-MAIN paging consoles are identified by device
ID, which is configured by a DIP switch.
BTQ-SL8
BTQ-SG8
DPM-MAIN
The DIP switch of device ID is followed by the binary code
with 5 digit (BTQ-SL8), 6 digit (BTQ-SG8), 4 digit (DPM-
MAIN).
The Device ID cannot be repeated. The range of ID can be
set as the table on the right.
DIP switch
BTQ-SL8
1~31
BTQ-SG8
0~63
DPM-MAIN
0~15
Please set the ID of BTQ-SL8, BTQ-SG8 and DPM-MAIN orderly, starting by the first number.
How-to:
1. Set the device ID for BTQ-SL8/SG8 and DPM-MAIN. See
the example of BTQ-SL8 on Figure 1, the order (4~0) of
the device ID is set as 00101 by the binary code. And the
ID will be converted by the decimal code as 5, that is to
say this device will be identified with the ID number of 5.
Figure 1
2. After the ID setting and the rest of the device hardware wiring are completed, go to Web Browser
> Device Management > System Size to build a BOUTIQUE system by adding the number of