Hardware installation & connection
BTQ-VM/SG/SL mounting
Mount the BTQ-VM4/8 controller in any standard
19-inch 2U audio equipment rack using the supplied
mounting brackets and screws. Installing a BTQ-SL8/
SG8 secondary unit is similar to installing a BTQ-
VM4/VM8, except the secondary units are installed in
19-inch 1U rack-mounting.
Consider leaving enough ventilation space above and
below the unit. Do not mount the controller directly
above the heat generating devices like power supplies
or power amplifiers.
BTQ-VM/SG/SL power supply
The BTQ-VM controller has two types of power supply input, AC mains and 48VDC for battery
backup via phoenix euro-block connector, and secondary unit by 24VDC.
Connection-mains power
Connection-battery backup
To activate the power supply of BTQ-VMW wallmount controller, connect the AC mains power
first, then 48VDC battery backup input. If the order is not correct, the BTQ-VMW can not be
operated.
Ethernet (RJ45)
Connect the BTQ-VM4/8 controller and BTQ-
SG8 unit to a computer by using CAT5/6
cable.
ATEIS network (digilink and global-net)
DIGI-LINK
The BTQ-VM4/8 controller has 1 digi-link port for BTQ-SL8 secondary unit. Use STP CAT5/6 cable
with shielded RJ45 connector to connect a BTQ-SL8 secondary unit to BTQ-VM4/8 controller. Up to
31 BTQ-SL8 units can be connected under the local digi-link network.