ATB AQUAmax BASIC Installation Instructions Manual Download Page 19

Installation instructions AQUAmax

®

 BASIC/CLASSIC 1-75 

 

ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / 
Art.-No.: 9060 0209 / Status: 17.01.2019 / Page 19 from 24 

 

 

Control unit ATB

control

© 

Control unit for the activation of small wastewater treatment plants of the types AQUA

max

®

 BASIC 

/ CLASSIC and AQUAPRIMO 
 

 

 
 

General and safety information 

With intended employment of the equipment no hazards whatsoever emanate from the unit. 
National applicable regulations and technical data are to be observed. 
Should the ATB

control

© 

3 be used for other purposes without the express approval of ATB WATER 

GmbH and/or if the following safety information is disregarded, this can lead to malfunction of or 
defects in the plant. In this case any liability is ruled out.  
Modifications to the unit are not permitted and lead to the loss of all claims under warranty. 
 
Do not operate any unit which indicates malfunctions, has been dropped or is damaged in any 
way. 
 

Features 

 Microprocessor 

controlled 

  USB connection for data readout and input 

  Splash water protected. Conditionally suitable for outside areas (IP54) 

 Wall 

mounting 

  Voltage failure detection system (UVS

®

  Potential-free contact for an additional alarm facility 

  Simple and rapid operation 

  Times for all parameters completely pre-programmed 

  Automatic run-in phase with suppression of excess sludge removal 

  Parameter settings freely selectable 

 Alarm 

interval 

  Alarm volume adjustable 

  Deployable for AQUA

max

®

 BASIC / CLASSIC and AQUAPRIMO 

 Plug-in 

  Winter operation and sludge removal mode for the reduction of the aeration times 

 

Summary of Contents for AQUAmax BASIC

Page 1: ...Innovations for clean water AQUAmax BASIC CLASSIC Installation Instructions...

Page 2: ......

Page 3: ...14 Installing of the AQUAmax Page 16 AQUAmax with compressed aeration ZB Page 18 Sampling bottle Sampling bypass Page 19 The ATBcontrol 3 control equipment Page 21 Cable connection test run Page 22 P...

Page 4: ...e complied with All tasks may be carried out by trained and qualified specialists with appropriate certificate of technical qualification The operator is to be instructed by the fitter With the connec...

Page 5: ...ra e 2 D 32457 Porta Westfalica www atbwater com Art No 9060 0209 Status 17 01 2019 Page 5 from 24 Explanation of the warning notices used Attention Danger due to electrical voltage Rotating parts Dan...

Page 6: ...A for suspension on chains 2 submers aerator AQUA 5 1 submersible pump ATBlift 2 as clarified water pump 1 submersible pump ATBlift 2 as excess sludge and charging pump 1 float switch 15 m connecting...

Page 7: ...e 1 control unit ATBcontrol 3 230 V panel mounting 1 sampling bottle made of PE with bracket 3 5 m PVC hose 25 mm for cleared water 5 0 m PVC hose 30 mm with screw connection for charging 18 m hose 16...

Page 8: ...PE with bracket 5 m PVC hose 25 mm for cleared water 5 0 m PVC hose 40 mm with screw connection for charging 18 m hose 16 mm f r aeration 25 m hose 25 mm f r aeration 3 membrane tube diffuser 1070 mm...

Page 9: ...is is not the case then a sampling possibility is to be installed in the SBR tank A 230 V energy supply is to be laid and fused separately as follows B 16 A and residual current circuit breaker 25 A 3...

Page 10: ...e lower edge of the inlet Close openings in the partition wall If necessary reseal tank joints Introduce empty pipe DN 100 for cable at any desired position Inlet and outlet must project ca 15 cm into...

Page 11: ...of the AQUAmax produces the connection to the last chamber of the primary settling stage Here the thick matter is separated from the influent Coarse interceptor and sludge store SBR aeration Inlet Out...

Page 12: ...nt Float Switch HW min all Types The switch off point of the float switch for all types is at the height of the centre selvedge between upper and lower part of the aerator housing The difference HW mi...

Page 13: ...the plastic bodywork If required loosen the securing screw and relocate the mounting bracket AQUAmax CLASSIC Z ZB Secure the stainless steel hooks supplied in such a way on the tank cover that the AQU...

Page 14: ...rimary settling chamber not the inlet chamber With single chamber primary settling an additional protective pipe or a scum board is to be provided for the immersion pipe Connect the outlet hose with t...

Page 15: ...Installation instructions AQUAmax BASIC CLASSIC 1 75 ATB WATER GmbH S dstra e 2 D 32457 Porta Westfalica www atbwater com Art No 9060 0209 Status 17 01 2019 Page 15 from 24...

Page 16: ...rovided This is also connected to the air distributor Multi and through the empty pipe in the tank with a 25 mm fabric hose From here the air is routed to the membrane diffusers via a 16 mm fabric hos...

Page 17: ...Amax BASIC CLASSIC 1 75 ATB WATER GmbH S dstra e 2 D 32457 Porta Westfalica www atbwater com Art No 9060 0209 Status 17 01 2019 Page 17 from 24 AQUAmax CLASSIC 1 16 ZB quarter chamber AQUAmax CLASSIC...

Page 18: ...outlet so far that the clear water cannot flow back Secure the hose with a pipe clamp to prevent it from slipping out If a non return flap is installed in the clear water hose or if the sampling bottl...

Page 19: ...alfunction of or defects in the plant In this case any liability is ruled out Modifications to the unit are not permitted and lead to the loss of all claims under warranty Do not operate any unit whic...

Page 20: ...as the sockets for the control unit and mains cable and the compressor s AQUAmax ZB mounting plate for one compressor 1 32 PE AQUAmax ZB mounting plate for two compressors 32 PE All tasks which nevert...

Page 21: ...ntrol unit takes place via three short stroke keys By pressing a key the display illumination is switched on lapses if no key is operated within 5 minutes Key functions Scroll upwards or downwards men...

Page 22: ...m the immersion pipe i e bubble free water exits whether the information plate which contains the disposal information is clearly visible and correctly mounted whether the outlet hose is correctly sec...

Page 23: ......

Page 24: ...Installation instructions AQUAmax BASIC CLASSIC 1 75 Art No 9060 0209 Status 17 01 2019...

Reviews: