Technical data
55
GB
7.8 Electrical connection
WARNING OF ELECTRICAL ENERGY!
RISK OF FATAL INJURY!
Live components have been installed
near this symbol. Covers bearing this sign
may only be removed by a certi
fi
ed skilled
electrician.
• The electrical connection must be carried out by a
quali
fi
ed electrician who is authorised to carry out
such work!
• Statutory regulations and the connection
speci
fi
cations issued by the local power supply
company must be strictly observed.
• When connecting the appliance it must be ensured
that there is a device which makes it possible to
universally disconnect it from the mains with a contact
opening width of at least 3mm. Line-protecting
switches, fuses or contactors are suitable cut-out
devices. When connecting and repairing the appliance
disconnect it from the electricity supply with one of
these devices.
• The earth wire must be su
ffi
ciently long so that if the
strain relief fails, the live wires of the connecting cable
are subjected to tension before the earth wire.
• Any
super
fl
uous cable must be removed from the
installation area beneath the appliance.
• Make sure that the local mains voltage is the same as
the voltage on the rating label.
• Full protection against accidental contact must be
ensured on installation.
• Attention: Incorrect connection may result in the power
electronics unit being destroyed.
• The appliance is only authorised for permanent
connection. It may not be connected with a shock-
proof plug.
Connected loads of the induction hob
380-415 2N 50/60Hz and 220-240 2N 50/60Hz
7400W
Component rated voltage: 220-240V
Connected loads of the extraction motor
220-240V 50/60Hz
168W
Induction connection
• There is no standard cable available for connecting
the induction part.
• To connect the appliance, unscrew the cover of the
connection socket on the underside of the appliance
in order to be able to access the terminal. After
connecting the appliance, replace the cover and
secure the connection cable with the strain relief
clamp.
• The connection cable must be at least H05 RR-F.
1x 32A
2x 16A
2x 16A
3x 16A
7.9 Putting the appliance into operation
Once the hob has been installed and the power supply
has been provided (mains connected) an automatic test
of the controls will be carried out and information for
Customer Service will be indicated.
Important: No items may be on the touch control sensor
keys when the appliance is being connected!
8 Technical data
Hob dimensions
height/ width/ depth . mm
150 x 800 x 515
Cooking zones
front left.................. Ø cm / kW
back left ................. Ø cm / kW
back right ............... Ø cm / kW
front right ............... Ø cm / kW
20/ 2.3 (3,0)
14.5/ 1.4 (1.85)
16/ 1.4 (2.1)
20/ 2.3 (3.0)
Hob with fan...................... kW
7.4
* Power when the power boost function is activated