Publication No. 981050 REV. A
PXIe-1209 User Manual
Astronics Test Systems
Operation 5-5
The Gate & Triggers configuration window consists of three different subwindows.
The
Gate & Triggers
configuration window is shown below:
Figure 5-7, Gate & Trigger Configuration Window
There are two different triggers that can be routed to / from the PXI backplane.
These are referred to a “M Trigger A” and “M Trigger B”. Each of these can be
selected as either an input to, or output from the pulse generator. The choices
are:
Trigger Input – this is a trigger input to the module
Output pulse – the pulse output is routed here
Output sync – the sync pulse is routed here
DDS SYNC_IN or SYNC_OUT – this is used to synchronize two pulse
generators. When this is selected, you can choose slave (SYNC_IN) for one
pulse generator and master (SYNC_OUT) for the second pulse generator.
The second sub-window is the
M-Triggers Routing
window as shown below:
Figure 5-8, M-Triggers Routing Window
When M-Trigger A is configured as a trigger input, the “M Trigger A input” selection
Summary of Contents for PXIe-1209