Chapter 4 INDIVIDUAL FORMATS FOR CONTROL COMMANDS
369
4.26
EXSYNC [51H]: Separate sync ON/OFF
Function:
This command turns ON or OFF of the separate sync of HS, VS and CS .
Sequence: Type 2
Command:
STX
1 byte
02H
EXSYNC
1 byte
51H
HS
1 byte
“0” = OFF, “1” = ON
VS
1 byte
“0” = OFF, “1” = ON
CS
1 byte
“0” = OFF, “1” = ON
ETX
1 byte
03H
Fig. 4-26-1
Data:
None