Chapter 6 EXAMPLES OF USAGE
469
6.3.2
Settings established using pattern select data setting command
Pattern select data registration: Command [20H 2AH]
Setting item
Setting value
Binary
ASCII
STX
0×02
VGCMD4
0×FD
SPTS4
0×20
0×2A
“*”
Program number
0×31
“1”
Delimiter
0×2C
“, “
Pattern select code = R
0×30
“0”
Delimiter
0×2C
“, “
Pattern select code = G
0×31
“1”
Delimiter
0×2C
“, “
Pattern select code = B
0×32
“2”
Delimiter
0×2C
“, “
Pattern select code = Color Bar
0×31
“1”
0×35
“5”
ETX
0×03
Note) ACK or the error status is received from the VG generator here.
ACK is received if the data has been transferred successfully.
Summary of Contents for VG-870