“User Settings” menu
Click on the menu item “User Settings” in the main menu at the left to have the corresponding input
mask displayed. The following input mask now appears:
Figure 43: User administration
You can create up to four users for the user interface of the U 168. The following three users have been
created as the default setting:
admin
user
controller
Users logged in as administrator can change all of the settings in the user interface. A number of set-
tings are not accessible for other user groups (e.g. “IP Interface Settings” table in the “Main” menu).
The password for all three users is “astro”.
To change the access data for a user account, or to create a new one, enter the preferred user name
in the input field
User name
. Then enter the preferred password in the input field
New Password
, and
confirm it by typing it in the input field
Retype New password
again.
N
OTE
:
A password must contain at least 5 characters. You can increase the minimum
requirements for passwords using the “Enforced Password Policy” option (see below).
To delete a user account, activate the corresponding checkbox
Delete
for the respective account in
the right column of the table.
The following settings can also be entered:
Timeout:
You can enter a time for the automatic logout, in minutes, in this input field. If no more
inputs are made in the user interface, then automatic logout will occur once the time entered here
has elapsed.
The time remaining until automatic logout is displayed under the main menu, in the left column of
the user interface.
Name, Location, Contact:
You can save a name for the system, the location and the contact
data for a person in these input fields. They are displayed in the status line.
Enforced Password Policy:
Activate the checkbox when a password should have a
minimum of 8 characters, and include at least one lower-case letter, one upper-case letter, one
number and one special character.
Disallow anonymous access:
Activate the checkbox when access to the content area
(tables) should only be possible after logging in.