AIR FOR COMBUSTION AND VENTILATION
Continued
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling
and one within 12" of the
fl
oor. Connect these
items directly to the outdoors or spaces open
to the outdoors. These spaces include attics
and crawl spaces. Follow the
National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Air for
Combustion and Ventilation
for required size
of ventilation grills or ducts.
IMPORTANT:
Do not provide openings
for inlet or outlet air into attic if attic has a
thermostat-controlled power vent. Heated air
entering the attic will activate the power vent.
Figure 3 - Ventilation Air from Outdoors
Outlet
Air
Ventilated
Attic
Outlet
Air
Inlet
Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
INSTALLATION
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining
uncon
fi
ned space. When ventilating to an
adjoining uncon
fi
ned space, you must provide
two permanent openings: one within 12" of the
ceiling and one within 12" of the
fl
oor on the
wall connecting the two spaces
(see options
1 and 2, Figure 2)
. You can also remove door
into adjoining room
(see option 3, Figure 2)
.
Follow the
National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Air for Combustion and
Ventilation
for required size of ventilation
grills or ducts.
Figure 2 - Ventilation Air from Inside
Building
Or
Remove
Door into
Adjoining
Room,
Option
3
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilation
Grills Into
Adjoining
Room,
Option 1
12"
12"
NOTICE: This appliance is intended
for use as supplemental heat. Use
this appliance along with your pri-
mary heating system. Do not install
this appliance as your primary heat
source. If you have a central heat-
ing system, you may run system’s
circulating blower while using hea
appliance ter. This will help circulate
the heat throughout the house. In the
event of a power outage, you can
use this appliance as your primary
heat source.
WARNING: A qualifi ed service
person must install appliance. Fol-
low all local codes.
WARNING: Any outside air ducts
and/or ash dumps in the fi replace
shall be permanently closed at time
of appliance installation.
WARNING: Seal any fresh air
vents or ash clean-out doors located
on fl oor or wall of fi replace. If not,
drafting may cause pilot outage
or sooting. Use a heat-resistant
sealant. Do not seal chimney fl ue
damper.