Astria.US.com
126823-01C
38
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
6. LED is blinking
7. Igniter cable is not connected
8. Igniter cable pinched or wet
9. Broken igniter cable.
10. Igniter electrode positioned
wrong.
11. Igniter electrode broken.
12. Control module sounds 2 cycles
of 3 beeps; LCD display may
show ROM ERROR
13. Control module sounds 2 cycles
of 5 beeps; LCD display may
show SUPPORT ERROR
14. Bad reception from remote
15. If LED on touch pad is continu-
ously on, the cable is connected
the wrong way.
16. The control module sounds 2
cycles of 5 beeps. The wiring
assembly from the control valve
is disconnected or broken.
6. This indicates the battery power is
low. Replace the batteries in the
power supply box.
7. Check the igniter connection at
both the control module and the
ODS pilot. Connect if loose.
8. Free igniter cable if pinched by
any metal or tubing. Keep igniter
cable dry.
9. Replace wire harness including
igniter cable.
10. Replace ODS pilot assembly.
11. Replace ODS pilot assembly.
12. Replace control module
13. Ground cable from control valve
wiring harness is not ground-
ing properly. Reposition spade
terminal so that it makes contact
with burner chassis metal or
valve body.
14. Change batteries in remote.
Check reception of signal from
a shorter distance. If still not
working, try changing the chan-
nel in the configuration menu.
If this does not
fi
x the problem,
reset the channel
(see Page 30
Channel Selection)
and follow the
instructions in Pairing on
Page
33
. Replace remote and control
module as a
fi
nal action.
15. Disconnect the touch pad be-
tween the long and short cables,
turn the short cable with the touch
pad over and reconnect.
16. Connect the wiring harness at the
control module. Replace the valve
assembly if all other cause/rem-
edies fail to correct his problem.
Either the remote or touch pad but-
tons are pressed to start the burner
ignition sequence and there is no
function or response.
(Continued