Section 2.  System Overview

Components

a.  eQ Controller

b.  Controller Mounting Plate

c.  Chlorinator Cell and Electrodes

d.  Screws for Mounting Plate

e.  50mm Injection Mixing Cell 

f.  50mm unions for glue-in pipe connection

g.  PVC Tube Acid Drum Connection and Venting Kit 

Table 1.  Chlorinator System Contents

2.3 

Specifications

2.3.1 

Salt Chlorinator System

Compact

Mid

Large

Nominal chlorine production

18 g/h

25 g/h

35 g/h

Nominal output amps

3.6 A

5.0 A

7.2 A

Required salt level

4000ppm

Power supply voltage

240 VAC - 50 Hz

Electric power

200 W

Protection index

IP43

Flow through the cell

Min. 80 Lpm

Max pressure in the cell

2.75 bar

Operating water temperature

10°C - 40°C

Table 2.  Salt Chlorinator System Specifications

Section 3.  Installation

3.1 

Controller Location

The controller should be located at or near the 

equipment pad, at least 3.5 metres or more away 

from the inside wall of the pool/spa, 1.5 metres off the 

ground, and within 2 meters of the cell. All national, 

state, and local codes are applicable.

Figure 2. 

Equipment Configuration, Acid Dosing

2.1 

Overview

The Viron e-Quilibrium Chlorinator incorporates a 

controller with inbuilt acid pump, an electrode cell for 

converting minerals or salts into chlorine, a mounting 

plate for the controller and tubes,  and injection points 

for the acid which controls your pool water pH. The 

intelligent software allows you to select and change 

your acid dosing ratio and intelligently adjusts the 

dose rate to match the output of the electrode. (The 

higher the output, the faster the pH will change and 

the more the controller will dose acid to compensate). 

However, you MUST test your pH every day for the first 

week and adjust your acid dose rate on the controller 

to achieve the correct pH level.

2.1.1 

pH Levels

Generally you should aim to have your pH at 7.4 to 7.8. 

The actual pH you choose for your pool will depend 

on the water quality in your area, the interior finish of 

your pool and the type of pool you have.

2.2 

Contents

Before starting, check that you have the correct parts 

as indicated in Figure 1 and Table 1. If any parts are 

missing or incorrect, p lease call your local distributor or 

technical support at 1300 763 021 for assistance.

2.2.1 

Viron e-Quilibrium Basic Chlorinator 

System

b

c

d

e

f

g

Figure 1. 

Chlorinator System Contents 

Summary of Contents for Viron EQ

Page 1: ...icable regulations Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in prop...

Page 2: ...es Chlorinator Installation Manual EQUIPMENT INFORMATION RECORD DATE OF INSTALLATION INSTALLER INFORMATION INITIAL PRESSURE GAUGE READING WITH CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL CONTROL P...

Page 3: ...t 13 5 4 Adjust pH Setpoint 13 Section 6 Bluetooth Setup 13 6 1 Connect via Bluetooth 13 6 2 Install the App 13 6 3 Pair the Chlorinator 13 6 4 Basic App Functions 14 Section 7 Pool Chemistry and Bala...

Page 4: ...10 minutes b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit spa water temperatu...

Page 5: ...during the use of a spa or hot tub to avoid unconsciousness and possible drowning Before entering a spa or hot tub measure the water temperature with an accurate thermometer Do not use a spa or hot t...

Page 6: ...Equipment Configuration Acid Dosing 2 1 Overview The Viron e Quilibrium Chlorinator incorporates a controller with inbuilt acid pump an electrode cell for converting minerals or salts into chlorine a...

Page 7: ...ng the unit in position on the wall or post the length of the PVC tubing provided should be measured and taken into consideration Ensure the controller and cell are close enough for the power supply l...

Page 8: ...t corrode the equipment It will be necessary to drill a second hole in the cap fitted tightly with a length of tubing which should then be vented outside the filter enclosure This procedure is recomme...

Page 9: ...is the most reliable and safest way to determine the level of the sanitiser in your water but is affected by other factors influencing the efficiency of the chlorine Water pH the use of sunscreens cya...

Page 10: ...ARC setting NOTE ARC setting is for service replacement only CELL REVERSAL PERIOD Do not change this setting without consulting with your local AstralPool dealer or service department Standard setting...

Page 11: ...In this model you can determine the dosing rate of the acid by selecting 1 to 10 in the pH set screen The Chlorinator will adjust the dosing level according to the chlorine production the higher the c...

Page 12: ...is enabled you can then set the pump speed for this timer If SLX Lighting has been enabled you can set the Lights to be in OFF or AUTO mode in this timer NB you can set the pump to be turned off in a...

Page 13: ...fibreglass vinyl liner Rely on a pool professional for additional advice on the correct pH Set Point for your pool 1 Press SET to change the pH balance of your pool 2 Use up down buttons to set your...

Page 14: ...ycles Time pH pH evolution 7 30 7 35 7 40 7 45 7 50 7 55 7 60 7 65 7 70 7 75 7 80 7 85 7 90 7 95 8 00 8 05 8 10 8 15 8 20 100 75 50 20 Factory Set Point 7 4 pH Figure 18 pH Evolution Graph 7 2 Chlorin...

Page 15: ...o swimming pools to make the available chlorine last longer It is often called stabiliser or sunscreen CyA bonds with chlorine ions which prevents the chlorine from oxidizing bacteria and other contam...

Page 16: ...ng an increased oxidization potential reading on the e Q chlorinator Cyanuric Acid Level Chlorine Level 2ppm 3ppm 4ppm 0 700 mv 725 mv 750 mv 10 550 mv 600 mv 625 mv 20 500 mv 525 mv 550 mv 50 350 mv...

Page 17: ...s disinfecting the water even at levels of 1ppm ORP remains the best method to measure the sanitiser s chlorine s effectiveness in the water At a reading of 750mv a virus kill time is as low as one se...

Page 18: ...rate if necessary NOTE The chlorine sensor may take 30 to 45 minutes to settle and provide the correct reading 8 3 2 Sensor Calibration Calibrate the pH sensor every 6 to 12 months 1 To Calibrate Pres...

Page 19: ...on and dose acid to achieve the desired levels The Viron e Quilibrium will ensure the pump operates until its primary two objectives are achieved Water is turned over 1 5 times on a 50 000 litre pool...

Page 20: ...as the unit adjusts to weather and environmental conditions 9 6 1 Extended Hours and High Speed Pump Operation Should Ai mode keep your pump in high speed for most of the day perform the following che...

Page 21: ...ump is set to OFF in all timers Modify timers so that the Pump is on in at least 1 timer Display blank No Power to Controller Fuse blown Plug in controller and ensure mains power available Call a tech...

Page 22: ...g Fan 2030037 1 10 Label Facia LABEL256 1 11 Main Cover 950902 1 12 PCB User 71401 1 13 Screws for User PCB 395201 4 14 Wall Mount Bracket 950905 1 15 Cell Cable Strain Relief 20028 1 16 Power Cable S...

Page 23: ...or place of purchase Claims must include the serial number and model this information can be found on the product installation date and name of the installer Shipping costs are not included i the war...

Page 24: ...019 Fluidra S A All rights reserved This document is subject to change without notice Fluidra Group Australia Pty Ltd 219 Woodpark Road Smithfield NSW2 2164 Australia 1 300 186 875 www astralpool com...

Reviews: