background image

5

Viron e-Quilibirum Series Chlorinator    

Installation Manual

4

Viron e-Quilibirum Series Chlorinator    

Installation Manual

Section 1.  Important Safety Instructions

READ AND FOLLOW ALL INSTRUCTIONS

All electrical work must be performed by a licensed electrician and conform to all national, state, and local 

codes. When installing and using this electrical equipment, basic safety precautions should always be followed, 

including the following:

  

WARNING

Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature of 

the body reaches a level several degrees above the normal body temperature of 37°C. The symptoms of hyperthermia 

include dizziness, fainting, drowsiness, lethargy, and an increase in the internal temperature of the body. The effects of 

hyperthermia include: 1) unawareness of impending danger; 2) failure to perceive heat; 3) failure to recognize the need to 

exit spa; 4) physical inability to exit spa; 5) fetal damage in pregnant women; 6) unconsciousness resulting in a danger of 

drowning.

 

  

DANGER

To reduce the risk of severe injury or death, do not remove the suction fittings of your spa or hot tub. Never operate a spa 

or hot tub if the suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate 

marked on the equipment assembly. 

  

WARNING

To Reduce the Risk of Injury -

a)  The water in a spa should never exceed 40°C. Water temperatures should remain between 38°C and 40°C. The water in 

a spa should never exceed 40°C. Water temperatures between 38°C and 40°C are considered safe for a healthy adult. 

Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes.

b)   Since excessive water temperatures have a high potential for causing fetal damage during the early months of 

pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 38°C. Before entering a spa 

or hot tub, the user should measure the water temperature with an accurate thermometer since the tolerance of water 

temperature-regulating devices varies.

d)  The use of alcohol, drugs, or medication before or during spa or hot tub use may lead to unconsciousness with the 

possibility of drowning.

e)  Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, 

or diabetes should consult a physician before using a spa.

f)  Persons using medication should consult a physician before using a spa or hot tub since some medication may induce 

drowsiness while other medication may affect heart rate, blood pressure, and circulation.

  

WARNING

Risk of electric shock - 

Install at least 3.5 metres from the inside wall of the pool and/or hot tub using non-metallic 

plumbing.

Do not use spas or hot tubs unless all suction guards are installed to prevent body and hair entrapment.
People using medications and/or having an adverse medical history should consult a physician before using a spa or hot 

tub.
This product is NOT suitable for use on Spa Pools UNLESS the OPTIONAL pH sensor has been purchased and installed

.

 

When used on Spa Pool applications, AstralPool strongly recommend the purchase and installation of a chlorine sensor in 

addition to the pH sensor.
This product is NOT suitable for use on Indoor swimming pools UNLESS the pH and Chlorine sensors have been purchased 

and installed.
Take extreme care when handling the pH adjuster which is either sulphuric acid or hydrochloric acid.  Wear gloves, eye 

protection and breathing protection.

Summary of Contents for Viron EQ

Page 1: ...icable regulations Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in prop...

Page 2: ...es Chlorinator Installation Manual EQUIPMENT INFORMATION RECORD DATE OF INSTALLATION INSTALLER INFORMATION INITIAL PRESSURE GAUGE READING WITH CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL CONTROL P...

Page 3: ...t 13 5 4 Adjust pH Setpoint 13 Section 6 Bluetooth Setup 13 6 1 Connect via Bluetooth 13 6 2 Install the App 13 6 3 Pair the Chlorinator 13 6 4 Basic App Functions 14 Section 7 Pool Chemistry and Bala...

Page 4: ...10 minutes b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit spa water temperatu...

Page 5: ...during the use of a spa or hot tub to avoid unconsciousness and possible drowning Before entering a spa or hot tub measure the water temperature with an accurate thermometer Do not use a spa or hot t...

Page 6: ...Equipment Configuration Acid Dosing 2 1 Overview The Viron e Quilibrium Chlorinator incorporates a controller with inbuilt acid pump an electrode cell for converting minerals or salts into chlorine a...

Page 7: ...ng the unit in position on the wall or post the length of the PVC tubing provided should be measured and taken into consideration Ensure the controller and cell are close enough for the power supply l...

Page 8: ...t corrode the equipment It will be necessary to drill a second hole in the cap fitted tightly with a length of tubing which should then be vented outside the filter enclosure This procedure is recomme...

Page 9: ...is the most reliable and safest way to determine the level of the sanitiser in your water but is affected by other factors influencing the efficiency of the chlorine Water pH the use of sunscreens cya...

Page 10: ...ARC setting NOTE ARC setting is for service replacement only CELL REVERSAL PERIOD Do not change this setting without consulting with your local AstralPool dealer or service department Standard setting...

Page 11: ...In this model you can determine the dosing rate of the acid by selecting 1 to 10 in the pH set screen The Chlorinator will adjust the dosing level according to the chlorine production the higher the c...

Page 12: ...is enabled you can then set the pump speed for this timer If SLX Lighting has been enabled you can set the Lights to be in OFF or AUTO mode in this timer NB you can set the pump to be turned off in a...

Page 13: ...fibreglass vinyl liner Rely on a pool professional for additional advice on the correct pH Set Point for your pool 1 Press SET to change the pH balance of your pool 2 Use up down buttons to set your...

Page 14: ...ycles Time pH pH evolution 7 30 7 35 7 40 7 45 7 50 7 55 7 60 7 65 7 70 7 75 7 80 7 85 7 90 7 95 8 00 8 05 8 10 8 15 8 20 100 75 50 20 Factory Set Point 7 4 pH Figure 18 pH Evolution Graph 7 2 Chlorin...

Page 15: ...o swimming pools to make the available chlorine last longer It is often called stabiliser or sunscreen CyA bonds with chlorine ions which prevents the chlorine from oxidizing bacteria and other contam...

Page 16: ...ng an increased oxidization potential reading on the e Q chlorinator Cyanuric Acid Level Chlorine Level 2ppm 3ppm 4ppm 0 700 mv 725 mv 750 mv 10 550 mv 600 mv 625 mv 20 500 mv 525 mv 550 mv 50 350 mv...

Page 17: ...s disinfecting the water even at levels of 1ppm ORP remains the best method to measure the sanitiser s chlorine s effectiveness in the water At a reading of 750mv a virus kill time is as low as one se...

Page 18: ...rate if necessary NOTE The chlorine sensor may take 30 to 45 minutes to settle and provide the correct reading 8 3 2 Sensor Calibration Calibrate the pH sensor every 6 to 12 months 1 To Calibrate Pres...

Page 19: ...on and dose acid to achieve the desired levels The Viron e Quilibrium will ensure the pump operates until its primary two objectives are achieved Water is turned over 1 5 times on a 50 000 litre pool...

Page 20: ...as the unit adjusts to weather and environmental conditions 9 6 1 Extended Hours and High Speed Pump Operation Should Ai mode keep your pump in high speed for most of the day perform the following che...

Page 21: ...ump is set to OFF in all timers Modify timers so that the Pump is on in at least 1 timer Display blank No Power to Controller Fuse blown Plug in controller and ensure mains power available Call a tech...

Page 22: ...g Fan 2030037 1 10 Label Facia LABEL256 1 11 Main Cover 950902 1 12 PCB User 71401 1 13 Screws for User PCB 395201 4 14 Wall Mount Bracket 950905 1 15 Cell Cable Strain Relief 20028 1 16 Power Cable S...

Page 23: ...or place of purchase Claims must include the serial number and model this information can be found on the product installation date and name of the installer Shipping costs are not included i the war...

Page 24: ...019 Fluidra S A All rights reserved This document is subject to change without notice Fluidra Group Australia Pty Ltd 219 Woodpark Road Smithfield NSW2 2164 Australia 1 300 186 875 www astralpool com...