Astralpool P320 XT P520 XT Installation Manual Download Page 9

9

viron xt series 2 pumps   

Installation Manual

8

viron xt series 2 pumps   

Installation Manual

Section 4.  Installation

4.1 

Pump Location

WARNING

To Reduce the Risk of Fire, install pool equipment in an area 

where leaves or other debris will not collect on or around 

the equipment. Keep surrounding area clear of all debris 

such as paper, leaves, pine-needles and other combustible 

materials.

AstralPool recommends installing the pump within 

30 cm (1 ft) above water level. The pump should not 

be elevated more than 152 cm (5 ft). If the pump is 

located below water level, isolation valves (check 

valves) must be installed on both the suction and 

return lines to prevent back flow of pool water during 

any routine or required servicing. 

   WARNING

A check valve can interfere with the proper 

operation of certain Suction Vacuum Release 

System (SVRS) products. To avoid possible en-

trapment hazard, serious injury, or death, make 

sure to review the operation/owners manual of 

your particular SVRS product before installing the 

check valve.

NOTE:

 

When the pool equipment is located below the 

pool surface a leak can result in large scale water 

loss or flooding. AstralPool cannot be responsible 

for such water loss or flooding or damage caused 

by either occurrence.

1. 

Install the pump such that any disconnecting means 

and/or junction boxes for power connection are within 

sight of the pump and at least five feet horizontally 

from the edge of the pool and/or spa. Choose a 

location that will minimize turns in the piping.

2. 

Place the pump on a solid foundation that will not 

vibrate. To further reduce the possibility of vibration 

noise, bolt the pump to the foundation.

3. 

Ensure that the foundation has adequate drainage to 

prevent the pump motor from getting wet.

4. 

Make sure the pump has the proper ventilation to 

prevent the motor from overheating. Overheating due 

to lack of cooling voids warranty.

5. 

Allow plenty of space for any maintenances by leaving 

a clear area around the pump.

6. 

Provide adequate lighting if the equipment is in a 

potentially dark area.

Pipe Size

Maximum Flow Suction

(6 feet per second)

Maximum Flow 

Discharge

(8 feet per second)

38 mm

(1½”)

140 LPM

(37 GPM)

189 LPM

(50 GPM)

51 mm

(2”)

235 LPM 

(62 GPM)

322 LPM

(85 GPM)

64 mm

(2½”)

333 LPM 

(88 GPM)

454 LPM

(120 GPM)

76 mm

(3”)

515 LPM 

(136 GPM)

697 LPM

(184 GPM)

102 mm

(4”)

886 LPM 

(234 GPM)

1185 LPM

(313 GPM)

4.1.1 

Installation Recommendations

1. 

To help prevent difficulty in priming, install the suction 

pipe without high points (above inlet of pump - 

inverted “U”s, commonly referred to in plumbing as an 

airlock) that can trap air. For installations of equipment 

up to 30 m (100 ft) from the water, refer to Table 1, the 

pipe sizing chart. For installations of equipment more 

than 30 m (100 ft) from the water, the recommended 

pipe size must be increased to the next size.

Bad Installation

(Air Lock)

Bad Installation

(90° Elbow Too Close)

Figure 5. 

Viron XT Series 2 Pump Incorrect Piping 

Installations

Summary of Contents for P320 XT P520 XT

Page 1: ...standards and any other local applicable regulations Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices...

Page 2: ...R MODEL CONTROL PANEL MODEL SERIAL NUMBER NOTES For full warranty terms and conditions and to register your warranty simply visit www astralpool com au warranty and complete your details Or scan the Q...

Page 3: ...1 Normal Operation 14 5 2 Starting Up the Pump 14 5 3 Pump Lid Removal 14 5 4 Conduct Pressure Test 15 Section 6 Viron XT Series 2 Pump Controls 16 6 1 Viron XT Series 2 Pump Control Panel 16 6 2 Spee...

Page 4: ...ceptable standard WARNING To reduce the risk of property damage or injury do not attempt to change the backwash multiport slide or full flow valve position with the pump running WARNING AstralPool Pum...

Page 5: ...e pump dry for any length of time will cause severe damage and will void the warranty WARNING To minimize risk of severe injury or death the filter and or pump should not be subjected to the piping sy...

Page 6: ...3 feet apart centre to centre See Figure 1 The system must be built to include at least two 2 suction outlets drains connected to the pump whenever the pump is running However if two 2 suction outlet...

Page 7: ...rate for your pool In addition special applications such as in floor cleaning or programming water features are enabled using the time clock and speed selection for different times of day The P520XT...

Page 8: ...iption Quantity 1 Viron XT Series 2 Pump 1 2 50 mm Union Nut 2 3 50mm Universal Union Tail 2 4 50mm Universal Union O ring 2 Table 1 XT Pump Parts 3 2 Technical Specifications Power P320XT 85 Kw outpu...

Page 9: ...ive feet horizontally from the edge of the pool and or spa Choose a location that will minimize turns in the piping 2 Place the pump on a solid foundation that will not vibrate To further reduce the p...

Page 10: ...from only one main drain At least two main drains must be connected to the pump when it is in operation However if two main drains run into a single suction line the single suction line may be equipp...

Page 11: ...IF USING A DIFFERENT BRAND HEATER All pool suction outlets and plumbing must be properly installed in compliance with applicable entrapment protection standards such as AS2610 2 Listed certified to t...

Page 12: ...e not to exceed 45 degrees 7 Pumps must be either supplied by an isolating transformer or supplied through a residual current device RCD with a rated residual operating current not exceeding 30mA 4 4...

Page 13: ...d by these devices The Viron P320XT and P520XT must have its in built timer deactivated if the pump operating times and speeds are to be operated by the compatible AstralPool Salt Chlorinator EQ RolaC...

Page 14: ...the user interface display Viron XT Series 2 Pump primes 30 faster than conventional maximum speed Viron XT Series 2 Pump automatically limits maximum speed according to the system s total dynamic hea...

Page 15: ...in death serious injury or property damage Be sure all air is properly purged out of the system before operating DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR LEAKS WARNING ELECTRICAL SHOCK...

Page 16: ...special purpose flow rates may include but are not limited to operating spa jets operating water falls or water features operating a suction pool cleaner High Speed is generally set up to backwash you...

Page 17: ...gain to set minutes and then press enter again to set AM or PM 5 Press Auto Power button to accept 6 The LCD screen will quickly flash 3 times to indicate the new setting has been accepted 6 3 3 Setti...

Page 18: ...d above normal high speed We recommend high speeds for Priming 4 PRIMING TIME will now appear on the screen Prime period is defaulted to 5 minutes and high speed Use the up and down arrows to change t...

Page 19: ...ods deactivated Pump speed can be changed from pump or controller 240V Power 24V Communication Data VX Salt Chlorinator TIMER CLOCK DAY Chlorine Output Set Point Decrease SAFETY BACKWASH POOL MODE SPA...

Page 20: ...16 Viron XT Series 2 Pump with RJ12 Cable Connection Viron XT Series 2 Pump is connected to Viron Heater or Other Compatible AstralPool Heater via RJ12 cable Viron Heater Status Viron XT Series 2 Pump...

Page 21: ...re release valve on the filter and make sure it is clean and ready for operation 10 Turn on the power to the pump Once all the air has been evacuated from the filter close the pressure release valve 7...

Page 22: ...n the surfaces surrounding the control to prevent ant and insect ingress Repeat every three months or as necessary Note Regular maintenance is important to ensure long life and trouble free performanc...

Page 23: ...nter season or other scheduling conflicts Check for debris build up in the skimmer basket This can cause reduced flow to the pump Also ensure that any suction cleaners are disconnected as this can be...

Page 24: ...24 viron xt series 2 pumps Installation Manual Section 9 Spare Parts 9 1 Series 2 Model P320XT and P520XT 1 2 9 10 11 12 13 8 14 3 5 7 21 22 17 18 16 19 23 20 15 4 6...

Page 25: ...NG SEAL PLATE 70030 1 1 13 SEAL PLATE SP40030 1 1 14 SEAL PLATE TO WET END BOLTS 40175 6 6 15 MOTOR RETAINING BOLT 40173 4 4 15 M8 HEX BRASS NUT 40272 6 6 16 MOTOR FOOT 4005002 1 1 16 MOTOR FOOT RUBBE...

Page 26: ...TOP TIME TIMER 4 START TIME TIMER 4 STOP TIME CURRENT TIME LOW MED HIGH TIMER 2 LOW SPEED TIMER 2 MED SPEED TIMER 2 HIGH SPEED LOW MED HIGH TIMER 3 LOW SPEED TIMER 3 MED SPEED TIMER 3 HIGH SPEED LOW M...

Page 27: ...ow Rate L min Overdrive High Speed 2850 RPM Medium Speed 2000 RPM Low Speed 1325 RPM 0 100 200 300 400 500 0 0 5 0 10 0 15 0 20 0 25 0 11 2 Series 2 Model P520XT Total Head m Flow Rate L min Overdrive...

Page 28: ...2020 Fluidra S A All rights reserved This document is subject to change without notice Fluidra Group Australia 219 Woodpark Road Smithfield NSW 2164 Australia 1 300 186 875 www astralpool com au...

Reviews: