                                            WARNING

SUCTION HAZARD. Can cause serious injury or death. Do not use this pump for wading pools, 

shallow pools, or spas containing bottom drains, unless pump is connected to at least two (2) 

functioning suction outlets.  

  WARNING

Pump suction is hazardous and can trap and drown or disembowel bathers. Do not use or 

operate swimming pools, spas, or hot tubs if a suction outlet cover is missing, broken, or loose. 

The following guidelines provide information for pump installation that minimizes risk of injury to users of 

pools, spas, and hot tubs:

Entrapment Protection 

- The pump suction system must provide protection against the hazards of 

suction entrapment.

Suction Outlet Covers

 - All suction outlets must have correctly installed, screw-fastened covers in 

place. All suction outlet (drain) covers must be properly maintained. They must be replaced if cracked, 

broken, or missing. Drain covers must be listed/certified to the latest published edition of ANSI

®

/ASME

®

 

A112.19.8 or its successor standard, ANSI/APSP-16. In Australia, AS1926.3 is also an acceptable 

standard. The pool must be shut down and bathers must be restricted from entering the pool until any 

cracked, broken, or missing drain covers are replaced.

Number of Suction Outlets Per Pump

 - Provide at least two (2) hydraulically-balanced suction outlets, 

with covers, as suction outlets for each circulating pump suction line. The centers of the suction outlets 

(suction outlets) on any one (1) suction line must be at least three (3) feet apart, centre to centre. See

 

Figure 1.

The system 

must

 be built to include at least two (2) suction outlets (drains) connected to the pump 

whenever the pump is running. However, if two (2) suction outlets run into a single suction line, the 

single suction line may be equipped with a valve that will shut off both suction outlets from the pump. 

The system shall be constructed such that it shall not allow for separate or independent shutoff or 

isolation of each drain. See Figure 1.
Additional pumps can be connected to a single suction line as long as the requirements above are met.

Water Velocity

 - The maximum water velocity through the suction outlet assembly and its cover for any 

suction outlet must not exceed the suction outlet assembly and its cover’s maximum design flow rate.  

The suction outlet (drain) assembly and its cover must comply with the latest version of ANSI

®

/ASME

®

 

A112.19.8, the standard for Suction Fittings For Use in Swimming Pools, Wading Pools, Spas,and Hot 

Tubs, or its successor standard, ANSI/ASME APSP-16. In Australia, AS1926.3 is also an acceptable 

standard.

Testing and Certification

 - Suction outlet covers must have been tested by a nationally recognized 

testing laboratory and found to comply with the latest published edition of ANSI/ASME A112.19.8 or 

its successor standard, ANSI/APSP-16, the standard for 

Suction Fittings For Use in Swimming pools, 

Wading Pools, Spas, and Hot Tubs

. In Australia, AS1926.3 is also an acceptable standard.

Fittings

 - Fittings restrict flow; for best efficiency use fewest possible fittings (but at least two (2) suction 

outlets). 

Avoid fittings that could cause an air trap. 
Pool cleaner suction fittings must conform to applicable International Association of Plumbing and 

Mechanical Officials (IAPMO) standards.

Summary of Contents for P320 XT P520 XT

Page 1: ...standards and any other local applicable regulations Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices...

Page 2: ...R MODEL CONTROL PANEL MODEL SERIAL NUMBER NOTES For full warranty terms and conditions and to register your warranty simply visit www astralpool com au warranty and complete your details Or scan the Q...

Page 3: ...1 Normal Operation 14 5 2 Starting Up the Pump 14 5 3 Pump Lid Removal 14 5 4 Conduct Pressure Test 15 Section 6 Viron XT Series 2 Pump Controls 16 6 1 Viron XT Series 2 Pump Control Panel 16 6 2 Spee...

Page 4: ...ceptable standard WARNING To reduce the risk of property damage or injury do not attempt to change the backwash multiport slide or full flow valve position with the pump running WARNING AstralPool Pum...

Page 5: ...e pump dry for any length of time will cause severe damage and will void the warranty WARNING To minimize risk of severe injury or death the filter and or pump should not be subjected to the piping sy...

Page 6: ...3 feet apart centre to centre See Figure 1 The system must be built to include at least two 2 suction outlets drains connected to the pump whenever the pump is running However if two 2 suction outlet...

Page 7: ...rate for your pool In addition special applications such as in floor cleaning or programming water features are enabled using the time clock and speed selection for different times of day The P520XT...

Page 8: ...iption Quantity 1 Viron XT Series 2 Pump 1 2 50 mm Union Nut 2 3 50mm Universal Union Tail 2 4 50mm Universal Union O ring 2 Table 1 XT Pump Parts 3 2 Technical Specifications Power P320XT 85 Kw outpu...

Page 9: ...ive feet horizontally from the edge of the pool and or spa Choose a location that will minimize turns in the piping 2 Place the pump on a solid foundation that will not vibrate To further reduce the p...

Page 10: ...from only one main drain At least two main drains must be connected to the pump when it is in operation However if two main drains run into a single suction line the single suction line may be equipp...

Page 11: ...IF USING A DIFFERENT BRAND HEATER All pool suction outlets and plumbing must be properly installed in compliance with applicable entrapment protection standards such as AS2610 2 Listed certified to t...

Page 12: ...e not to exceed 45 degrees 7 Pumps must be either supplied by an isolating transformer or supplied through a residual current device RCD with a rated residual operating current not exceeding 30mA 4 4...

Page 13: ...d by these devices The Viron P320XT and P520XT must have its in built timer deactivated if the pump operating times and speeds are to be operated by the compatible AstralPool Salt Chlorinator EQ RolaC...

Page 14: ...the user interface display Viron XT Series 2 Pump primes 30 faster than conventional maximum speed Viron XT Series 2 Pump automatically limits maximum speed according to the system s total dynamic hea...

Page 15: ...in death serious injury or property damage Be sure all air is properly purged out of the system before operating DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR LEAKS WARNING ELECTRICAL SHOCK...

Page 16: ...special purpose flow rates may include but are not limited to operating spa jets operating water falls or water features operating a suction pool cleaner High Speed is generally set up to backwash you...

Page 17: ...gain to set minutes and then press enter again to set AM or PM 5 Press Auto Power button to accept 6 The LCD screen will quickly flash 3 times to indicate the new setting has been accepted 6 3 3 Setti...

Page 18: ...d above normal high speed We recommend high speeds for Priming 4 PRIMING TIME will now appear on the screen Prime period is defaulted to 5 minutes and high speed Use the up and down arrows to change t...

Page 19: ...ods deactivated Pump speed can be changed from pump or controller 240V Power 24V Communication Data VX Salt Chlorinator TIMER CLOCK DAY Chlorine Output Set Point Decrease SAFETY BACKWASH POOL MODE SPA...

Page 20: ...16 Viron XT Series 2 Pump with RJ12 Cable Connection Viron XT Series 2 Pump is connected to Viron Heater or Other Compatible AstralPool Heater via RJ12 cable Viron Heater Status Viron XT Series 2 Pump...

Page 21: ...re release valve on the filter and make sure it is clean and ready for operation 10 Turn on the power to the pump Once all the air has been evacuated from the filter close the pressure release valve 7...

Page 22: ...n the surfaces surrounding the control to prevent ant and insect ingress Repeat every three months or as necessary Note Regular maintenance is important to ensure long life and trouble free performanc...

Page 23: ...nter season or other scheduling conflicts Check for debris build up in the skimmer basket This can cause reduced flow to the pump Also ensure that any suction cleaners are disconnected as this can be...

Page 24: ...24 viron xt series 2 pumps Installation Manual Section 9 Spare Parts 9 1 Series 2 Model P320XT and P520XT 1 2 9 10 11 12 13 8 14 3 5 7 21 22 17 18 16 19 23 20 15 4 6...

Page 25: ...NG SEAL PLATE 70030 1 1 13 SEAL PLATE SP40030 1 1 14 SEAL PLATE TO WET END BOLTS 40175 6 6 15 MOTOR RETAINING BOLT 40173 4 4 15 M8 HEX BRASS NUT 40272 6 6 16 MOTOR FOOT 4005002 1 1 16 MOTOR FOOT RUBBE...

Page 26: ...TOP TIME TIMER 4 START TIME TIMER 4 STOP TIME CURRENT TIME LOW MED HIGH TIMER 2 LOW SPEED TIMER 2 MED SPEED TIMER 2 HIGH SPEED LOW MED HIGH TIMER 3 LOW SPEED TIMER 3 MED SPEED TIMER 3 HIGH SPEED LOW M...

Page 27: ...ow Rate L min Overdrive High Speed 2850 RPM Medium Speed 2000 RPM Low Speed 1325 RPM 0 100 200 300 400 500 0 0 5 0 10 0 15 0 20 0 25 0 11 2 Series 2 Model P520XT Total Head m Flow Rate L min Overdrive...

Page 28: ...2020 Fluidra S A All rights reserved This document is subject to change without notice Fluidra Group Australia 219 Woodpark Road Smithfield NSW 2164 Australia 1 300 186 875 www astralpool com au...

Reviews: