6.3.6
Using In-Built Timer with Non-compliant
Chlorinator
1.
We do not recommend the use of the pump timers
when a non compliant chlorinator or chemical doser
is supplied water flow by the Viron P320 or P520 XT
pump.
2.
In this case, the pump operating hours should be
controlled by the chlorinator time clock and the pump
plugged into the chlorinator. This is a safety measure
provided for by most chlorinator manufacturers.
3.
However, it is important to deactivate the inbuilt
pump timers.
4.
Have Pump in “MANUAL OFF”
5.
Toggle Menu until “CONF” is displayed on the LCD
screen
6.
Press and HOLD “enter” for 3 seconds
7.
Toggle Menu until “TMR” appears.
8.
Press UP or Down buttons to turn “TMR OFF”
9.
Press “ENTER” to accept
10. Press “AUTO” to return to main menu.
11. When cycling through the Menu button TMR will no
longer appear
12. You will no longer be able to automatically have the
speed of the pump changed during different times of
the day.
13. However, if you wish for a period where the pump
operates at a high speed, for example to circulate the
water vigorously for a part of the daily filtration, you
can use the PRIMING setting to do so.
6.3.7
Using Priming Program to Circulate Water
at Higher Flow Rate
1.
Have PUMP in MANUAL OFF
2.
Press MENU BUTTON TWICE until PRIM appears on the
screen
3.
Press ENTER To show current Speed, use UP
DOWN buttons to Adjust speed. Adjusts in 25 RPM
increments. Once Speed is selected Press ENTER.
(Similarly to HIGH Speed, PRIME speed can be set to
overdrive mode by using the Up button to increase
the speed above normal high speed) We recommend
high speeds for Priming
4.
PRIMING TIME will now appear on the screen. Prime
period is defaulted to 5 minutes and high speed. Use
the up and down arrows to change the Priming period
From 2 minutes up to 120 minutes. Press ENTER to
accept, Screen will Flash
5.
Press “Auto” to exit the programming.
6.3.8
Using Pump with AstralPool-Compliant
External Control
AstralPool manufactures Salt Chlorinators, EQ
chemical dosing units or the Viron Connect Touch
Screen Control system which can control both the
operating times of the all Viron XT Series 2 pumps
PLUS the speed the pump operates at during each
timer period.
For the P320XT and P520XT, you must enable the
communication port and disable the Pump in built
timers.
1.
Toggle Menu until CONF (configure) appears. Hold
enter for 3 seconds.
2.
Toggle Menu until “TMR” appears.
3.
Press UP or Down buttons to turn “TMR OFF”.
Remember, you are now using the external control
to set the pump operating hours, so the pump timer
must be turned off.
4.
Press “enter” to accept
5.
Toggle menu until SYS (system) appears. Press the up
or down button and turn to “ON”. The Viron P320XT
or P520XT will accept the start, end and pump speed
instructions from the AstralPool compliant control
chlorinator EQ & Rolachem dosing controller or Viron
Connect Touch Screen Control.
6.
Press “auto” to return to main menu.
7.
The time will still be visible on the LCD display
however, the timer function in the menu setting will
no longer appear. Toggle the menu button will now
only display PRIM (priming program), CLK (clock
setting) and CONF (Configuration menu).
8.
Refer to your AstralPool compliant Chlorinator, “EQ”,
RolaChem Dosing Control or Viron Connect Touch
Screen Control manual for details of programming the
pump speed and operating hours.