viron xt series 2 pumps
Installation Manual
18
viron xt series 2 pumps
Installation Manual
6.4
XT Pumps and Other Products
6.4.1
Use With Remote Controls
6.4.1.1
Viron XT Series 2 Pump Standalone
• 4 built in timer periods in pump
• 3 programmable speed settings
• Low, medium or high speed can be selected in each
timer period
• Priming period can be selected from 2 to 120 minutes
• Prime RPM can be adjusted
240V Power
24V Communication Data
Figure 13.
Viron XT Series 2 Pump and Remote Control
6.4.1.2
Viron XT Series 2 Pumps and Compatible VX Timer
Model Chlorinator or Viron Salt Chlorinator
• Timer periods set up in chlorinator
• Low, medium or high speed can be selected for each
timer period
• Data cable directly connects pump to chlorinator
• XT Pump to be set up with timer periods deactivated
• Pump speed can be changed from pump (from
chlorinator early 2012)
240V Power
24V Communication Data
VX Salt Chlorinator
TIMER
CLOCK
DAY
Chlorine O
utput Set Poin
t
Decrease
SAFETY
BACKWASH
POOL
MODE
SPA
MODE
Increase
HOUR
MIN
Low Salt
No Flow
Auto
On
Off
VXT
Figure 14.
Viron XT Series 2 Pump, Compatible VX Timer
Model Chlorinator and Remote Control
6.4.1.3
Viron XT Series 2 Pumps, VX S (Non-timer) Model
Chlorinator and Viron Connect 10 Remote Control
System
• Timer periods set up in controller
• 3 programmable speed settings on pump
• Select low, medium or high speed during each timer
period
• Data cables connecting pump/chlorinator/controller
• XT Pump to be set up with timer periods deactivated
• Pump speed can be changed from pump or controller
240V Power
24V Communication Data
VX Salt Chlorinator
TIMER
CLOCK
DAY
Chlorine O
utput Set Poin
t
Decrease
SAFETY
BACKWASH
POOL
MODE
SPA
MODE
Increase
HOUR
MIN
Low Salt
No Flow
Auto
On
Off
VXT
Timers
Home
Favorites
Pool & Spa
Lighting
Heating
Chemistry
more...
Viron Connect 10
Figure 15.
Viron XT Series 2 Pump, VX S (Non-timer Model
Chlorinator and Viron Connect 10 Remote
Control System
6.4.2
Use with Suction Cleaners
When connecting a suction cleaner to the Viron XT
Series 2 pump, it essential that full prime is achieved
on the pump prior to connecting the cleaner hose.
During operation at low speeds, the pump may only
operate with partial prime in the hair and lint pot
chamber.
To operate a suction cleaner on your pump;
1.
Choose the speed button (low, medium or high) on
which the pump will operate when the suction cleaner
is connected.
2.
Allow pump to operate for a minimum of 2 minutes to
allow a full prime to be achieved.
3.
Connect cleaner plate and hose to skimmer/wall
suction only after all air has been purged from the top
of the hair and lint pot of your Viron Pump.
4.
Adjust speed (with increase or decrease buttons) at
which the cleaner will travel to all areas of the pool.
Factory set medium speed will usually operate all
suction cleaner types in most pools. If using the Low
Speed setting, it will usually be necessary to increase
the low speed to ensure the suction cleaner operates
reliably.
5.
When cleaner is no longer required, disconnect and
remove hose/cleaner plate from system. Select the
lowest filtration speed that keeps your pool clean.