Section 9.
Final Installation Check
In order to ensure proper function and successful
installation, it is required that the operation of the
appliance be fully tested and confirmed. The following
sections (9.1 - 9.7) address the initial start up and
shut down of the heater. A successful intial startup
test must be performed in order to complete the
installation.
9.1
Operating Instructions
Follow the instructions outlined below to start the
heater. Refer to the Lighting and Shutdown Instructions
label on the inside lid panel of the heater. See
Figure 24
All questions should be directed to technical support
at 1300 186 875. Additional information can be found
at www.AstralPool.com.au.
WARNING
If you do not follow the instructions below exactly, a
fire or explosion may result, causing property damage,
personal injury or loss of life.
9.2
Important Safety Information
1. Read Before You Start:
• This appliance does not have a pilot light. It is
equipped with an ignition device, which
automatically lights the heater. Do NOT try to light
the burners by hand.
• BEFORE OPERATING
, smell all around the
appliance for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor.
9.2.1
What To Do If You Smell Gas
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call the Fire
Department.
• Use only your hand to switch on or off the gas
control switch. Never use tools. If the switch
appears broken or will not move, don’t try to
repair it, call a qualified service technician. Force or
attempted repair may result in fire or explosion.
• Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and to replace
any part of the control system which has been
under water.
9.3
First Time Start-up Procedure
WARNING
Vent pipes and heater tops get hot! These surfaces can
cause serious burns. Do not touch these surfaces while
the heater is in operation.
Do not use this heater if any part has been under water.
Immediately call a qualified service technician to inspect
the heater and replace any part of the control system
and any gas control which has been under water.
Should overheating occur or the gas supply fail to shut
off, turn off the manual gas control valve to the heater.
Do not attempt repairs on the gas controls or appliance.
Tampering is dangerous and voids all warranties
• Confirm that pool water is flowing normally
through the pool system and equipment.
• If it is a new pool or spa installation, operate the
filter pump with the heater off long enough to
completely clean the water. This will remove any
installation residue from the water.
• Clean the filter before starting the heater.
• Start the heater in either Pool or Spa mode. See
Figure 24
.
• Start the heater. See
Figure 24.
• When the heater starts, confirm there is adequate
water flow. See
Section 5
for details.
9.4
Lighting Instructions
Refer to the Lighting and Shutdown Instructions. See
Figure 24
located inside the top panel.
• STOP! Read IMPORTANT SAFETY INFORMATION
in previous section.
• Set temperature thermostat controls to their
lowest setting and turn off the controller. Make
sure the display shows GAS HEATER IS OFF.
• Turn off all electrical power to the heater at the
junction box.
• This appliance is equipped with an ignition device
which automatically lights the heater.
Do NOT
try
to light the burner by hand.
• Remove the heater rear or top panel.
• Unplug gas valve. See
Figure 24
.
• Wait five (5) minutes to clear out any gas, then
smell for gas, including near the floor. IF YOU
SMELL GAS, STOP! Follow instructions in Section
9.2.1.
• If no gas is detected, plug gas valve back in.
• Replace the rear panel and/or top.
• Turn on electrical power to the heater.
• Turn the controller ON by pressing POOL or SPA
and set the temperatures as necessary.
NOTE: If the heater does not start, check that the
filter pump is ON, the filter is clean and that water
is flowing to the pool. If the heater still does not
operate, follow the procedure in Section
8.4
to turn
off gas supply to the heater.