Section 6. Water Connections
Install pool system components with connections as
illustrated in
Figure 6
. Any configuration other than as
illustrated in
Figure 6
can affect the operation of the
water pressure switch. Locating the heater above or
below the pool water surface can also affect operation
of the water pressure switch.
NOTE:
When pool equipment is located below the pool
surface, AstralPool is not responsible for any large scale
water loss, fl ooding or damage caused by a leak.
CAUTION
The pool equipment must be protected from back-
siphoning of water. If there is any chance of back-
siphoning, provide a check valve between the pool and
the fi lter pump inlet.
6.1
Pump Sizing
The flow bypass within the heater manifold will
accommodate flows rates delivered to the heater from
a minimum of 114 Litres per minute (lpm) (30 gpm) to
a maximum flow of 379 lpm (100 gpm.)
CAUTION
The system water pump must be capable of providing
no less than 114 lpm (30 gpm) of fl ow through the
heater. Flow rates at less than 114 lpm (30 gpm) may
cause nuisance operation causing the heater to turn off
or damage to the heater.
MODEL
MIN LPM (GPM)
MAX LPM (GPM)
IXI 200
114 (30)
379 (100)
IXI 370
114 (30)
379 (100)
Table 4.
Recommended Flow Rate Adjustment
SUCTION
OUTLETS*
EXTERNAL MANUAL
BYPASS VALVE
HEATER
FILTER
CHECK VALVE
(Always install a corrosion resistant check
valve when any sanitation equipment,
including erosion feeders and salt
chlorination systems are installed,
see section 5.4
for more details)
PUMP
POOL/SPA
3 WAY VALVE
SPA DRAIN*
(Suction Outlet)
SKIMMER
SPA RETURN
POOL
RETURN
a.
a.
EXTERNAL MANUAL
BY-PASS DETAIL:
USE WHEN FILTRATION RATE
EXCEEDS 378 lpm (100 gpm). REFER
TO THE MANUFACTURER’S
RECOMMENDATIONS IF USING A
DIFFERENT BRAND HEATER.
*All pool suction outlets and plumbing
must be properly installed in compliance
with applicable entrapment protection
standards such as AS1926.2010
Figure 9.
Typical Water Piping Confi guration