The baud rate setting (BR) is responsible for the limitation of the
output rate. Please check the dependence of measuring
frequency/ output frequency with baud rate and data format of
serial interface output (SD) in the tables below. If measuring
frequency will be higher as the values in the table, some of the
measured distance values will be lost. Please double check with a
new setting of measuring frequency MF the BR setting.
Table 6: Binary output - Maximum measurement frequency (MF
max
)
Output values
Distance
Distance
+ signal quality
Distance
+ temperature
Distance
+ signal quality
+ temperature
Output data
format
SD 2 0
SD 2 1
SD 2 2
SD 2 3
Length of
output data
2
3
3
4
Baud rate
Maximum output frequency = MF
max
with SA 1
9600
470
300
300
220
19200
900
600
600
450
115200
5750
3800
3800
2880
230400
11600
7700
7700
5800
460800
23200
15500
15500
11600
921600
40000
30300
30300
23000
2000000
40000
40000
40000
34000
The number of transmitted distance values is directly connected to
the parameters MF and SA (average):
Output rate = MF x SA
Example:
With MF = 1 and SA = 1000 one measurement is done every
second, but the output time is about 17 minutes (1000 s).