Mounting
Regulations
In accordance with “Guidelines for electronic locking systems in escape route
doors,” the terminal must be positioned in such a way that the EMERGENCY OPEN
button is placed between 850 mm and 1200 mm above the upper edge of the
finished floor. A height of 850 mm to the centre of the EMERGENCY OPEN button
is recommended there. Further regulatory requirements can be found in
respective local building ordinances.
Fig. 2 :
Preparatory tasks
2
Control lines
e.g.: J-Y (ST)Y
I
Traction relief
I
For flexlines:
use wire end-sleeves
1
Mounting