FM336 9800 TCWI1 Series
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express
written permission of Corbin Russwin, Inc. is prohibited.
2
Prep door according to supplied Corbin Russwin Inc. door marker.
This device is not handed, however the Trim assembly is handed. Door should be fitted and
hung. Verify box label for size of exit device, function and hand.
1
Attach Fire Stop Plate
using (2) #8x 1/2"
Self-Tapping Screws
for Wood and Metal
Doors
CL of 1-1/2 Dia.
Fire Stop Plate required
for fire rated doors
(2) 1/8” Diameter
Holes Required
Hole for ribbon cable
1-1/2#
Outside of
Door
The Optional Conduit is available
for Non Fire rated doors to provide
weather protection for exterior
door applications. It is included in
the M99 Weathersesal Gasketing
Kit when ordered with the device.
If ordered separately, order part
number 794F909.
Install conduit half with recessed
panel "Not For Use On Fire Door"
visible from outside of door.
Outside
Left Hand
Reverse
“LHR”
Right Hand
Reverse
”RHR”
4) Installation Instructions
Inside