Assa Abloy Corbin Russwin Access 800 9800 TCPIP1 Series Installation Instructions Manual Download Page 13

FM336 9800 TCWI1 Series

13         

Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company. 

All rights reserved. Reproduction in whole or in part without the express  

written permission of Corbin Russwin, Inc. is prohibited.

A

  Frame Harness Installation

Components and wire harness supplied by McKinney: Suggested installation. 

RJ45-M 

Molex-M

Cable

: CA

T 5e or higher

24 A

WG shielded, 100ohm

B-Splice

 Crimp Connector

Ceiling

Supplied by CI

Each of the hinge-side harness connectors should end up threaded 

through a different access hole and matched to the  same size pin 

connector from the door harness:

•  4-pin male Molex connector.
•  6-pin male Molex connector with ground wire.

Notes:
•  Connectors only go on one way. They cannot be plugged  

to incorrect position. 

•  Do not force and do not offset connectors.
•  Be sure they are completely seated (flush).

Cut end / ceiling-side PoE harness: 

TIA/EIB-568-B Standard Wiring

1  

2  3

  4  5  6  

8

Pair Number

Wire

PIN

1

White/Blue

White/Blue

5

Blue

4

2

White/Orange

White/Orange

1

Orange

2

3

White/Green

White/Green

3

Green

6

4

White/Brown

White/Brown

7

Brown

8

Do not confuse pair numbers with pin numbers. A pair number is 

used for reference only (eg: 10BaseT Ethernet uses pairs 2 & 3). The 

pin numbers indicate actual physical locations on the plug and jack.

1.  Feed cut end of harness into hole on hinge-side through single  

access hole. 

2.  Push one of the connectors back through hole and feed into  

separate access hole.

Hinge side of PoE harness:

B

6-pin F

4-pin M

6-pin M

4-pin F

B

Drain Wire

Frame

PoE Hinge (Patent Pending)

Frame-Side

Harness

Assembly

(15' length)

24AWG 

Stranded 

Drain 

Wire for 

Earth 

Ground in 

15' Frame 

Harness

Cable drain wire  

concealed in  

shrink tubing

7) PIP (PoE) Installation Wiring (Continued)

Hinge-side harness connectors:

•  4-pin male molex connector
•  6-pin male molex connector with ground wire

Lock-side harness connectors:

•  Ring terminal
•  (2) 4-pin connectors 

Summary of Contents for Corbin Russwin Access 800 9800 TCPIP1 Series

Page 1: ...result in damage to the lock and void the factory warranty Important The accuracy of the door preparation is critical for proper functioning and security of this lock Misalignment can cause premature...

Page 2: ...fications were met This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device m...

Page 3: ...or both indoor and exterior applications A weather protective gasket is recommended for exterior applications HID and iCLASS are registered trademarks of HID Global Corporation 2 General Description S...

Page 4: ...8 Corbin Russwin Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin Inc is prohibited 3 9800 TCWI1 Series Tri...

Page 5: ...ire Stop Plate using 2 8x 1 2 Self Tapping Screws for Wood and Metal Doors CL of 1 1 2 Dia Fire Stop Plate required for fire rated doors 2 1 8 Diameter Holes Required Hole for ribbon cable 1 1 2 Outsi...

Page 6: ...s NOTE Cylinders longer than 1 1 8 29mm will require collars Refer to Cylinder Chart Below 2 When required cut cylinder tailpiece Correct length is 1 16 to 3 16 2 to 5 mm beyond cylinder housing cam A...

Page 7: ...of gasket with the edge of the escutcheon Outside Trim Assembly 1 Route motor harness pigtail thru 3 4 diameter hole C on inside of door and out other side through trim assembly prep Connect to trim...

Page 8: ...le connector and ground wire from outside of door through fire stop plate and hole in door 1b For non fire rated exit devices feed keypad ribbon cable connector and ground wire through hole in door 2...

Page 9: ...over to inside controller escutcheon making sure to line up tabs with retaining slots in battery cover Secure with security screw using security T20 bit CAUTION DOOR MUST REMAIN OPEN DURING INSTALLATI...

Page 10: ...devices with 9834 Series cylinder override trims a Insert key into cylinder and rotate b While holding key in rotated position operate outside lever to retract latch c They should rotate freely and o...

Page 11: ...type door harness cut connectors off product and hard wire or consult factory for appropriate mating harness 6 3 ElectroLynx Connector System Notes The system is designed to be installation friendly w...

Page 12: ...ale RJ45 connector from harness to end user provided facility cable Supplied by End User PoE Switch PoE Lock Ceiling Supplied by CI C B A PoE Patch Panel Drain Wire Terminated on Rack D Ground Ring Te...

Page 13: ...ing side PoE harness TIA EIB 568 B Standard Wiring 1 2 3 4 5 6 7 8 Pair Number Wire PIN 1 White Blue White Blue 5 Blue 4 2 White Orange White Orange 1 Orange 2 3 White Green White Green 3 Green 6 4 Wh...

Page 14: ...f installation may vary Refer to appropriate sections for in structions 1 Prop door open 2 Tape the two lock side 4 pin connectors to the ring terminal 3 Using the ring terminal carefully fish the ass...

Page 15: ...18 Corbin Russwin an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin is prohibited ASSA ABLOY is the global leade...

Page 16: ...18 Corbin Russwin an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin is prohibited ASSA ABLOY is the global leade...

Reviews: